DeviceNet Gateway


Signal type

Bit

Signal

name

Description

15 RUN

Gateway Unit
normal output

This signal remains ON while the Gateway
Unit is operating normally.
The signal is synchronized with the
illumination of the LED (RUN) on the front
face of the unit.

14 G.ER

Gateway Unit
error detection output

This signal turns ON when a major shutdown
failure has been detected.
The signal is synchronized with the
illumination of the LED (G.ER) on the front
face of the unit.

13 T.ER

SIO communication
error detection output

This signal turns ON when a SIO link
communication error has been detected.
The signal is synchronized with the
illumination of the LED (T.ER) on the front
face of the unit.

12 TPC

Port switch ON output The status of the port switch on the front face

of the unit is output.
This signal is ON while the port switch is ON.

11 MOD4

Mode setting switch 4
output

10 MOD3

Mode setting switch 3
output

9 MOD2

Mode setting switch 2
output

8 MOD1

Mode setting switch 1
output

The setting status of each pin of the mode
setting switch is output.

This bit will turn ON (change to 1) when the
switch is turned ON.

7 Major

V.4

6 Major

V.2

5 Major

V.1

The major version
number is output as a
three-bit binary value.

4 Minor

V.16

3 Minor

V.8

2 Minor

V.4

1 Minor

V.2

Status

signal 0

0 Minor

V.1

The major version
number is output as a
five-bit binary value.

The Gateway version information is output.
You may need to check this information in
certain situations, such as when the Gateway
encountered a problem. Provide the
necessary wiring so that these signals can be
read by the PLC.

Example) If the version is 1.03, the major

version number is “1” (data: 001),
while the minor version number is
“3” (data: 00011).

15

LNK15

Linked Axis No. 15

14 LNK14

14

13 LNK13

13

12 LNK12

12

11 LNK11

11

10 LNK10

10

9 LNK9

9

8 LNK8

8

7 LNK7

7

6 LNK6

6

5 LNK5

5

4 LNK4

4

3 LNK3

3

2 LNK2

2

1 LNK1

1

PLC input

Status

signal 1

0 LNK0

0

Link connection of an axis selected for link
connection by any one of CFG15 to 0 will
become enabled when the MON signal is
turned ON. The signal corresponding to each
axis whose link connection is enabled turns
ON.