2) free assignment using a configurator – IAI America RCM-GW-DV User Manual
Page 44
38
DeviceNet Gateway
(2) Free assignment using a configurator
By using a DeviceNet configurator, slaves can be assigned respectively to four blocks, including
output area blocks 1 and 2 and input area blocks 1 and 2, in a desired node address order within
each block. By using this free assignment function, up to 16 master units can be installed in a single
PLC.
[1] One block has a maximum of 500 channels (i.e., there are 500 output channels x 2 and 500
input channels x 2). Each item can be assigned in desired areas within the applicable range
specified below:
I/O relay:
0000~6143CH
Internal auxiliary relay:
W000~W511CH
Keep relay:
H000~H511CH
Data memory:
D00000~D32767
Expansion data memory: E00000~E32767
[2] The blocks can be assigned in a desired order, and the assigned block areas and node
addresses in each block can also be sequenced freely.
[3] A slave having more than 16 I/O points occupies multiple channels.
[4] A slave having no more than 16 I/O points occupies either the lower byte or upper byte.
*1 DeviceNet configurator
A software program for building, setting and managing DeviceNet networks using graphical screen
interfaces. This software provides the following functions:
• Free assignment of remote I/O functions
• Setting of slave parameters
• Monitoring of master and slave communication statuses
CPU unit
Output area
Output
(OUT)
block 1
Input area
Input (IN)
block 1
Each block can occupy any position. For example, the
blocks can be arranged in a sequence of IN block 1,
OUT block 2, IN block 2 and OUT block 1.
Addresses can be
freely sequenced.
Addresses can be
freely sequenced.
Addresses can be
freely sequenced.
Addresses can be
freely sequenced.
From each
slave
To each
slave
Address
Address
Address
Address
Address
Address
Address
Address
Output
(OUT)
block 2
Input (IN)
block 2