DeviceNet Gateway

(2) Free assignment using a configurator

By using a DeviceNet configurator, slaves can be assigned respectively to four blocks, including
output area blocks 1 and 2 and input area blocks 1 and 2, in a desired node address order within
each block. By using this free assignment function, up to 16 master units can be installed in a single
PLC.






























[1] One block has a maximum of 500 channels (i.e., there are 500 output channels x 2 and 500

input channels x 2). Each item can be assigned in desired areas within the applicable range
specified below:

I/O relay:

0000~6143CH

Internal auxiliary relay:

W000~W511CH

Keep relay:

H000~H511CH

Data memory:

D00000~D32767

Expansion data memory: E00000~E32767

[2] The blocks can be assigned in a desired order, and the assigned block areas and node

addresses in each block can also be sequenced freely.

[3] A slave having more than 16 I/O points occupies multiple channels.
[4] A slave having no more than 16 I/O points occupies either the lower byte or upper byte.

*1 DeviceNet configurator

A software program for building, setting and managing DeviceNet networks using graphical screen
interfaces. This software provides the following functions:

• Free assignment of remote I/O functions
• Setting of slave parameters
• Monitoring of master and slave communication statuses

CPU unit

Output area

Output

(OUT)

block 1

Input area

Input (IN)

block 1

Each block can occupy any position. For example, the
blocks can be arranged in a sequence of IN block 1,
OUT block 2, IN block 2 and OUT block 1.

Addresses can be
freely sequenced.