DeviceNet Gateway

Caution

For movement data that must be specified directly from the PLC using numerical values, the settings
of corresponding “default parameter values” are not applied. This means that if any of these data is not
specified numerically, the actuator will not operate or an alarm will generate.

The table below summarizes how to specify movement data in each operation mode.



Command specification

Mode

Specified data

Position number

specification

Direct numerical

specification

Positioner

operation

Simple direct

operation

Position

Position table

PLC numerical

specification

Position table

PLC numerical

specification

Speed Position

table

(Parameter) *1

PLC numerical

specification

Position table

(Parameter) *1

Position table

(Parameter) *1

Acceleration/
deceleration

Position table

(Parameter) *1

PLC numerical

specification

Position table

(Parameter) *1

Position table

(Parameter) *1

Positioning
band

Position table

(Parameter) *1

PLC numerical

specification

Position table

(Parameter) *1

Position table

(Parameter) *1

Push-current
limiting value

Position table

PLC numerical

specification

Position table

Position table

*1 (Parameter) indicates that the default parameter value will be applied when the applicable data is not

set in the position table.