IAI America RCM-GW-DV User Manual
Page 51
45
DeviceNet Gateway
I/O Signal Details
Signal type
Bit
Signal
name
Description Details
Command
position
number
Six-bit
data
(b13-8)
PC 32 to
PC1
Specify the command position number using a
binary value. *1
7.2 (11)
b7
-
Cannot be used.
-
b6
-
Cannot be used.
-
b5
-
Cannot be used.
-
b4
SON
Servo on command
7.2 (7)
b3
STP
Pause command
7.2 (5)
b2
HOME
Home return command
7.2 (8)
b1
CSTR
Start command
7.2 (9)
PLC output
Control
signal
b0
RES
Reset command
7.2 (4)
Zone
signal
output 2
b15
ZONE2
*2
Zone
signal
output 1
b14 ZONE1
7.2 (13)
Completed
position
number
(alarm
output)
Six-bit
data
(b13-8)
PM32
to
PM1
The completed position number and zone signal
status are output. Read the completed position
number as a six-bit binary value.
If an alarm is present (= the ALM signal is ON), a
description of the alarm is output as the
completed position number.
(For the alarm descriptions to be output, refer to
the next table, “Alarm Description List.”
7.2 (12)
b7
EMGS
Emergency stop
7.2 (2)
b6
-
Cannot be used.
-
b5
PWR
Controller ready
7.2 (1)
b4
SV
Ready (servo is on)
7.2 (7)
b3 MOVE
Moving
7.2
(6)
b2
HEND
Home return complete
7.2 (8)
b1
PEND
Position complete
7.2 (10)
PLC input
Status
signal
b0 ALM
Alarm
7.2
(3)
*1 The maximum number of positioning points is 16 under PIO control with ERC2-NP/PN controllers.
When the Gateway Unit is connected, however, up to 64 points can be specified.
*2 [ZONE 2] cannot be used with ERC2-NP/PN controllers.