DeviceNet Gateway

I/O Signal Details

Signal type

Bit

Signal

name

Description Details

Command

position

number

Six-bit

data

(b13-8)

PC 32 to

PC1

Specify the command position number using a
binary value. *1

7.2 (11)

b7

-

Cannot be used.

-

b6

-

Cannot be used.

-

b5

-

Cannot be used.

-

b4

SON

Servo on command

7.2 (7)

b3

STP

Pause command

7.2 (5)

b2

HOME

Home return command

7.2 (8)

b1

CSTR

Start command

7.2 (9)

PLC output

Control

signal

b0

RES

Reset command

7.2 (4)

Zone

signal

output 2

b15

ZONE2

*2

Zone

signal

output 1

b14 ZONE1

7.2 (13)

Completed

position

number

(alarm

output)

Six-bit

data

(b13-8)

PM32

to

PM1

The completed position number and zone signal
status are output. Read the completed position
number as a six-bit binary value.
If an alarm is present (= the ALM signal is ON), a
description of the alarm is output as the
completed position number.
(For the alarm descriptions to be output, refer to
the next table, “Alarm Description List.”

7.2 (12)

b7

EMGS

Emergency stop

7.2 (2)

b6

-

Cannot be used.

-

b5

PWR

Controller ready

7.2 (1)

b4

SV

Ready (servo is on)

7.2 (7)

b3 MOVE

Moving

7.2

(6)

b2

HEND

Home return complete

7.2 (8)

b1

PEND

Position complete

7.2 (10)

PLC input

Status

signal

b0 ALM

Alarm

7.2

(3)


*1 The maximum number of positioning points is 16 under PIO control with ERC2-NP/PN controllers.

When the Gateway Unit is connected, however, up to 64 points can be specified.

*2 [ZONE 2] cannot be used with ERC2-NP/PN controllers.