3 cc-link interface – IAI America PCON-CFA User Manual
Page 93
4. PCON-CA/CF
A
CC-Link
87
4.3 CC-Link Interface
(1) Names of Each Section
The names of each section related to CC-Link are described as follows.
(2) Status LED Indication
The board operation status and network condition are obtained with the two LEDs located in the front of
the controller.
䂾
: Illuminating, 㬍 : OFF, 䃩 : Flashing
LED
Color Indication Status
Indication Description (Meaning)
䂾
x
An error occurs.
(CRC Error/Station No. (parameters) Setting Error/Baud Rate
Setting (parameters) Error)
x
Period between power up or software reset and the CC-Link
initialization completion
㬍
x
Under Normal Communication
ERR
OR
䃩
(0.4sec)
x
Station No. setting or communication speed setting is changed
during the communication.
䂾
x
Communicating normally
RUN
GN
㬍
x
Not communicating
SV/ALM Status Indicator LED
FG
SLD
DG
DB
DA
ERR
RUN
CC-Link Communication Connector
Status LED
PCB side : MSTBA2.5/5-G-5.08AU
(PHOENIX CONTACT)
Cable side : SMSTB2.5/5-ST-5.08AU