4. PCON-CA/CF
A
CC-Link
128
(12) Zone 1
(ZONE 1)
Zone 2
(ZONE 2)
Position Zone (PZONE)
These signals are turned ON when the current position of the actuator is within the set area and turned
OFF when the current position is out of the set area.
1) Zone 1, Zone 2
The zone is set using the user parameters.
The Zone 1 Signal is set using the parameter No. 1 “Zone 1 “+” Side” and No. 2 “Zone 1 “-” Side”.
The Zone 2 Signal is set using the parameter No. 23 “Zone 2 “+” Side” and No. 24 “Zone 2 “-” Side”.
The Zone 1 Signal and Zone 2 Signal become effective when the homing operation is completed.
After that, even during the servo OFF, it is effective.
2) Position Zone
The zone is set using the position table I/O data register.
In the case of the Position/Simplified Direct Value Mode, the PZONE signal is set using the position
table.
In the case of the Full Direct Value Mode, the PZONE signal is set using the Zone Value Register.
(*) In the Half Direct Value Mode, there is no PZONE signal.
The PZONE signal becomes effective with the movement command after the homing operation. After
that, even during the servo OFF, it is effective.
PLC Input Signal
PLC Input Signal
PLC Input Signal
Zone Signal
Actuator Operation
Home
Zone Setting
"-" Side
Zone Setting
"+" Side
"+" Direction