Scon-ca cc-link, Scon-ca applicable to cc-link actuator – IAI America PCON-CFA User Manual
Page 162
5. SCON-CA
CC-Link
156
1) Remote I/O Mode: This is the operation method using CC-Link, instead of PIO (24V I/O).
No. of Occupied Stations: One Station
Caution : There is no compatibility with Remote I/O Mode on SCON-C.
(SCON-C : Remote I/O Station, SCON-CA : Remote Device Station)
2) Position/Simplified Direct Value Mode: This is the operation method with the position No. set up.
Whether if setup the target position using a value directly by means
of the change over of the control signal, or using the value registered
on the position data, can be selected.
For “Speed, “Acceleration/Deceleration” and “Positioning Width”, use
the values already registered on the position data. The settable No.
of position data items is max 768 points.
No. of Occupied Stations: One Station
3) Half Direct Value Mode: This is the operation method with the “Speed”, “Acceleration/Deceleration”,
“Pressing Current Value” set up directly using the numerical values, in addition to
the “Target Position”.
No. of Occupied Stations: Two Stations
SCON-CA
not applicable to CC-Link
SCON-CA
applicable to CC-Link
Flat cable
Communications
cable
In the case of the connection using PIO
In the case of the connection using CC-Link
Target Position : 100.00mm
+
Position No.0
SCON-CA
applicable to CC-Link
Actuator
No.
0
Speed
[mm/s]
Acceleration
[G]
Deceleration
[G]
Pressing
[%]
300.00
0.30
0.30
0
Target Position : 100.00mm
Positioning Width : 0.10mm
Speed Setup : 100.0mm/s
Acceleration/Deceleration : 0.30G
Pressing Current Value : 50%
SCON-CA
applicable to CC-Link
Actuator