beautypg.com

6 communication speed setting – IAI America PCON-CFA User Manual

Page 23

background image

3.

ACON-C/CG, PCON-C/CG

CC-Link

17

3.6 Communication Speed Setting

The communication speed is set using the parameters.
Set the parameter No. 86 “FBRS: Filed Bus Communication Speed” using the RC personal computer
application software.
(Refer to “3.10 CC-Link Related Parameters”).

Set Value

Communication Speed

0: (Already set in system delivery)

156kbps

1

625kbps

2

2.5Mbps

3

5Mbps

4

10Mbps

* Entering any value except for the ones described above will

cause an “Excessive Input Value Error”.

Note: After the parameter setting, turn on the power to the controller again and return the mode toggle switch on the front

of the controller to “AUTO” side.
When the switch is set to “MANU”, the operation using PLC is not available.