5. SCON-CA
CC-Link
171
Parameter No. 25 setting
Force Control Mode 1
Force Control Mode 2
6
7
Classification Port
No.
Symbol
Signal Names
Symbol
Signal Names
0
PC1
ST0
Start position 0
1
PC2
ST1
Start position 1
2
PC4
ST2
Start position 2
3
PC8
ST3
Start position 3
4
PC16
Command position No.
ST4
Start position 4
5
6
7
Unavailable
Unavailable
8
CLBR
Loadcell Calibrarion
Command
CLBR
Loadcell Calibrarion
Command
9
BKRL
Forced brake release
BKRL
Forced brake release
10
RMOD
Operation mode
RMOD
Operation mode
11
HOME
Return to origin
HOME
Return to origin
12
*STP
Pause
*STP
Pause
13
CSTR
Positioning Start
Unavailable
14
RES
Reset
RES
Reset
PLC Output㸢
SCON-CA Input
15
SON
Servo ON Command
SON
Servo ON Command
0
PM1
PE0
Completed position 0
1
PM2
PE1
Completed position 1
2
PM4
PE2
Completed position 2
3
PM8
PE3
Completed position 3
4
PM16
Completion position
No.
PE4
Completed position 4
5
TRQS
Torque Level Status
TRQS
Torque Level Status
6
LOAD
Load Output Judgment
LOAD
Load Output Judgment
Status
7
CEND
Loadcell Calibration
Complete
CEND
Loadcell Calibration
Complete
8
PZONE/
ZONE1
Position zone status/
Zone 1
PZONE/
ZONE1
Position zone status/
Zone 1
9
RMDS
Operation Mode Status
RMDS
Operation Mode Status
10
HEND
Return to origin end
HEND
Return to origin end
11
PEND
Positioning end Signal
PEND
Positioning end Signal
12
SV
Operation preparation
end
SV
Operation preparation
end
13
*EMGS
Emergency stop
*EMGS
Emergency stop
14
*ALM
Alarm
*ALM
Alarm
SCON-CA
Output
㸢
PLC Input
15
*BALM
Battery Alarm
*BALM
Battery Alarm
The symbol with a * mark shows the ON signal in normal condition.
The signals describing as “Unavailable” are not controlled. (ON/OFF is undefined).