Acon-c/cg, pcon-c/cg, 1 operation modes and functions – IAI America PCON-CFA User Manual
Page 17
3.
ACON-C/CG, PCON-C/CG
CC-Link
11
3. ACON-C/CG, PCON-C/CG
3.1 Operation Modes and Functions
ACON or PCON applicable to CC-Link can be operated by means of selecting one mode out of the following
five operation modes.
* Set the Station Data for the Master Station to “ver 1, Remote Device Station”.
Operation Modes and Main Functions
Main Function
Remote I/O
Mode
Position /
Simplified Direct
Value Mode
Half Direct
Value Mode
Full Direct
Value Mode
Remote I/O
Mode 2
No. of Occupied
Stations
1 Station
1 Station
2 Stations
4 Stations
1 Station
Position Data
Setup Operation
㬍
䂾
(*1)
䂾
䂾
㬍
Speed/Acceleration
Direct Command
㬍
㬍
䂾
䂾
㬍
Pressing Operation
䂾
䂾
䂾
䂾
䂾
Current Position
Read
㬍
䂾
䂾
䂾
䂾
Current Speed
Read
㬍
㬍
䂾
䂾
㬍
Position No. Setup
Operation
䂾
䂾
㬍
㬍
䂾
Completed
Position No. Read
䂾
䂾
㬍
㬍
䂾
No. of Max.
Position Tables
512
768
Unused
Unused
512
(*1) For the position data items except for position data, operate the system with the position No. set up.
1) Remote I/O Mode
: This is the operation method using CC-Link, instead of PIO (24V I/O).
No. of Occupied Stations: One Station
Flat cable
ACON or PCON
not applicable to CC-Link
In the case of the connection using PIO
In the case of the connection using CC-Link
ACON or PCON
applicable to CC-Link
Communications
cable