IAI America PCON-CFA User Manual

Page 226

background image

5. SCON-CA

CC-Link

220

(* “ON” in the table shows the corresponding bit of “1” and “OFF” shows “0”.)

Signal Type

Bit Symbol

Description

Details

Current

Position

32bits

Data



32-bit Signed Integer
The unit is 0.01mm.
(Example)
Read Value: 000003FF

H

= 1023 (decimal system) = 10.23mm

* When it is read in hexadecimal notation, input the negative

value using a compliment of 2.

5.9 (2)

Command

Current

32bits

Data



32-bit Integer
It shows the current value in the current command.
The unit is mA.
Read Value: 000003FF

H

= 1023 (decimal system) = 1023mA

5.9 (2)

Current

Speed

32bits

Data



32-bit Signed Integer
It shows the current speed.
Positive Figure: Under movement in the opposite direction of home
Negative Figure: Under movement in the home direction
The unit is 0.01mm/sec.
(Example)
Read Value: 000003 FF

H

= 1023 (decimal system)

= 10.23mm/sec

* When it is read in hexadecimal notation, input the negative

value using a compliment of 2.

5.9 (2)

Alarm

code

16bits

Data



16-bit Integer
When an alarm is issued, the alarm code is output.
When any alarm is not issued, it is “0H”.
Refer to the instruction manual for the controller main body for
the details of the alarms.

5.9 (2)

b15

EMGS Emergency Stop: “ON” for Emergency Stop Status

5.7.11 (2)

b14

PWR Controller Ready: “ON” for Ready

5.7.11 (1)

b13 ZONE2 Zone 2: “ON” for the current position within the zone set range 5.7.11 (12)
b12 ZONE1 Zone 1: “ON” for the current position within the zone set range 5.7.11 (12)

b11

b10

b9



Unavailable



b8

RMDS

Operation Mode Status:
“OFF” for currently “AUTO” mode, “ON” for currently “MANU”
mode

5.7.11 (19)

b7

BALM

Warning for Absolute Battery Voltage Drop :
Turns ON at voltage drop

5.7.11 (28)

b6



Unavailable



b5

PSFL Pressing and a Miss: “ON” for pressing and a miss

5.7.11 (23)

b4

SV

Operation Ready: “ON” with Servo ON

5.7.11 (5)

b3

ALM Alarm: “ON” with alarm issue

5.7.11 (3)

b2

MOVE

Movement Signal:
“ON” with Actuator Movement

5.7.11 (9)

b1

HEND

Homing Completion
“ON” with Homing Completion

5.7.11 (6)

P

LC

In

pu

t

Status
Signal

b0

PEND

Positioning Completion Signal:
“ON” with Positioning Completion

5.7.11 (10)