4. PCON-CA/CF
A
CC-Link
108
4.7.5 Full Direct Value Mode (Remote Device Station: No. of Occupied Stations: Four
stations)
This is the operation mode with all the values (target position, speed, etc.) set up directly using values from
PLC.
Set each value in the I/O data register.
The robot cylinder's effective main functions that can be controlled using this mode, are as shown in the
following table.
Robot Cylinder Function
䂾
:Direct Control
㬍
:Disabled
Homing
䂾
Positioning
䂾
Speed, Acceleration and Deceleration Settings
䂾
Pitch Feeding (Inching)
䂾
Pressing Operation
䂾
Speed change during the movement
䂾
Different Acceleration Speed
䂾
Operation in Deceleration
䂾
Pause
䂾
Zone Signal Output
䂾
PIO Pattern Selection
㬍
(1) PLC Address Composition (* “n” shows the head register address for each axis).
Parameter
No.84
PCON-CA/CFA side
Input register
PLC side
PCON-CA/CFA side
Output register
PLC side
RY n0 to nF
RX n0 to nF
RY (n+1)0 to (n+1)F
RX (n+1)0 to (n+1)F
RY (n+2)0 to (n+2)F
RX (n+2)0 to (n+2)F
RY (n+3)0 to (n+3)F
RX (n+3)0 to (n+3)F
RY (n+4)0 to (n+4)F
RX (n+4)0 to (n+4)F
RY (n+5)0 to (n+5)F
RX (n+5)0 to (n+5)F
Occupied Area
RY (n+6)0 to (n+6)F
Occupied Area
RX (n+6)0 to (n+6)F
System Area
RY (n+7)0 to (n+7)F
System Area
RX (n+7)0 to (n+7)F
RWw (n+0)
RWr (n+0)
Target Position
RWw (n+1)
Current Position
RWr (n+1)
RWw (n+2)
RWr (n+2)
Positioning Width
RWw (n+3)
Command Current
RWr (n+3)
RWw (n+4)
RWr (n+4)
Speed
RWw (n+5)
Current Speed
RWr (n+5)
RWw (n+6)
Alarm Code
RWr (n+6)
Zone Value “+”
RWw (n+7)
RWr (n+7)
RWw (n+8)
RWr (n+8)
Zone Value “-”
RWw (n+9)
Occupied Area
RWr (n+9)
Acceleration
RWw (n+A)
RWr (n+A)
Deceleration
RWw (n+B)
Total moving count
RWr (n+B)
Pressing Current
Limit Value
RWw (n+C)
RWr (n+C)
Load Current
Threshold
RWw (n+D)
Total moving
distance
RWr (n+D)
Control signal 1
RWw (n+E)
Status Signal 1
RWr (n+E)
3
Control signal 2
RWw (n+F)
Status Signal 2
RWr (n+F)
Note: The Occupied Area stands for the area occupied by means of the setting of the number of remote device stations.
The System Area stands for the system area of the remote device station.
These areas are not used for any other purpose. Also take care about duplicating the use of the data register.