IAI America PCON-CFA User Manual
Page 124
4. PCON-CA/CF
A
CC-Link
118
Signal Type
Bit
Signal
name
Description
Details
b15
EMGS
Emergency Stop: “ON” for Emergency Stop Status
4.7.7 (2)
b14
PWR
Controller Ready: “ON” for Ready
4.7.7 (1)
b13
ZONE2
Zone 2: “ON” for the current position within the zone set
range
4.7.7 (12)
b12
ZONE1
Zone 1: “ON” for the current position within the zone set
range
4.7.7 (12)
b11
PZONE
Position Zone:
“ON” when the current position is within the position zone
set range
4.7.7 (12)
b10
LOAD
Load Output Judgment:
“ON” for Reached “OFF” for Not reached
[Refer to the instruction manual for the controller main body
for more information.]
4.7.7 (26)
b9
TRQS
Torque Level:
“ON” for Reached “OFF” for Not Reached
[Refer to the instruction manual for the controller main body
for more information.]
4.7.7 (27)
b8
RMDS
Operation Mode Status:
“OFF” for currently “AUTO” mode, “ON” for currently
“MANU” mode
4.7.7 (19)
b7
GHMS
Under Homing Operation: “ON” for Homing Operation
4.7.7 (6)
b6
PUSHS Under Pressing Operation: “ON” for Pressing Operation
4.7.7 (25)
b5
PSEL
Pressing and a Miss: “ON” for pressing and a miss
4.7.7 (23)
b4
SV
Operation Ready: “ON” with Servo ON
4.7.7 (5)
b3
ALM
Alarm: “ON” with alarm issue
4.7.7 (3)
b2
MOVE
Movement Signal: “ON” with Actuator Movement
4.7.7 (9)
b1
HEND
Homing Completion: “ON” with Homing Completion
4.7.7 (6)
PLC Input
Status
Signal 2
b0
PEND
Positioning Completion Signal: “ON” with Positioning
Completion
4.7.7 (10)