2. Interface Specifications

CC-Link

10

2. Interface Specifications

Item

Specification

Communications standard

CC-Link Ver1.10

Communications speed [Mbps]

10 / 5 / 2.5 / 0.625 / 0.156

Communications system

Broadcast polling system

Synchronization system

Frame synchronization system

Encoding system

NRZI

Transmission path format

Bus format (EIA RS485 conformance)

Transmission format

HDLC conformance

Error control system

CRC (X

16

+ X

12

+ X

5

+ 1)

Number of occupied stations

Remote device station 1 to 4 stations

Baud rate [Mbps]

10

5

2.5

0.625

0.156

Communications
cable length

(Note 1)

Total Cable Length [m]

100

160

400

900

1200

Connector (Controller side)

(Note 2)

MSTBA2.5/5-G-5.08AU
Connector Manufactured by PHOENIX CONTACT

Note 1 For T branch communication, refer to the Instruction Manuals for the master unit and PLC to be

mounted.

Note 2 The cable-side connector is a standard accessory.

SMSTB2.5/5-ST-5.08AU Connector Manufactured by PHOENIX CONTACT