IAI America PCON-CFA User Manual
Page 121
4. PCON-CA/CF
A
CC-Link
115
(* “ON” in the table shows the corresponding bit of “1” and “OFF” shows “0”.)
Address
Bit
Symbol
Functions
Details
Acceleration
16bits
Data
Deceleration
16bits
Data
16-bit Integer
Set the acceleration and deceleration in the movement.
The unit is 0.01G and the settable range is from1 to 300.
(Example)
When it is 0.30G, set it as “30”.
When the movement command is issued with the value of “0”
or bigger than the max. acceleration/deceleration value, an
alarm is output.
4.9 (3)
Pressing
Current
Limit
Value
16bits
Data
16-bit Integer
Set the current limit in the pressing operation.
The settable range is between 0 (0%) and 255 (100%).
The actual settable range varies depending on each actuator.
(Refer to the catalog or instruction manual for the actuator).
When the movement command is set with the value bigger
than the max. pressing current value, an alarm is issued.
4.9 (3)
Load
Current
Threshold
16bits
Data
16-bit Integer
Set the current threshold in this register when whether or not
the load current exceeds the threshold is judged.
The settable range is between 0 (0%) and 255 (100%).
When the judgment is not to be performed, set it to “0”.
4.9 (3)
b15
b14
b13
b12
b11
Unavailable
b10
SMOD
Stop Control Mode: “ON” for servo control while it is stopped
4.7.7 (28)
b9
ASO1
Stop
Mode 1
b8
ASO0
Stop
Mode 0
Select stop mode while standing by
ASO1
ASO0
Functions
OFF
OFF
Disable
(Servo is ON at all times)
OFF
ON
Sever turns OFF in time set
in Parameter No. 36
ON
OFF
Sever turns OFF in time set
in Parameter No. 37
ON
ON
Sever turns OFF in time set
in Parameter No. 38
4.7.7 (30)
b7
MOD1
b6
MOD0
Acceleration/Deceleration Mode
MOD1
MOD0
Functions
OFF
OFF
Trapezoid Pattern
OFF
ON
S-shaped Motion
ON
OFF
First-Order Lag Filter
4.7.7 (29)
b5
b4
Unavailable
P
LC
O
ut
pu
t
Control
signal 1
b3
INC
Incremental Command
“OFF” for Absolute Position Command, “ON” for Relative
Position Command
4.7.7 (24)