3.
ACON-C/CG, PCON-C/CG
CC-Link
52
(5) Servo ON Command (SON)
Operation Ready
(SV)
When “SON” signal is turned “ON”, the servo-motor is turned “ON”. When the servo-motor is turned ON,
the Status Indicator LED (Refer to “3.3 CC-Link Interface”) on the front surface of the controller
illuminates in green.
The “SV” signal is synchronized with this LED.
Function:
Using the “SON” signal, the turning ON/OFF of the controller is available.
While the “SV” signal is ON, the controller's servo-motor is turned “ON” and the operation becomes
available.
The relationship between the “SON” signal and “SV” signal is as follows.
PLC Input Signal
PLC Output Signal
(PLC→ACON, PCON)