IAI America PCON-CFA User Manual
Page 91
4. PCON-CA/CF
A
CC-Link
85
4) Full Direct Value Mode : This is the operation method with all the values (“Target Position”, “Speed”,
“Acceleration/Deceleration”, etc.) related to the position control set up directly
using the numerical values.
No. of Occupied Stations: Four Stations
5) Remote I/O Mode 2
: This is the operation method using CC-Link, instead of PIO (24CV I/O).
The current position and command current value reading functions are added to
the functions of 1).
No. of Occupied Stations: One Station
PCON-CA/CFA
not applicable to CC-Link
PCON-CA/CFA
applicable to CC-Link
Flat cable
Communications
cable
In the case of the connection using CC-Link
In the case of the connection using PIO
Target Position : 100.00mm
Positioning Width : 0.10mm
Speed Setup : 100.0mm/s
Acceleration : 0.30G
Deceleration : 0.30G
Pressing Current Value : 50%
Load Current Threshold : 0
Zone + : 50.00mm
Zone - : 30.00mm
PCON-CA/CFA
applicable to CC-Link
Actuator