(3) I/O Signal Allocation
The controller's I/O port signal varies depending on the parameter No. 25 setting. (Refer to instruction
manual for the controller main body for more information).
ACON
Parameter No. 25 setting
Positioning mode
Teaching mode
256 point mode
0
1
2
Classification Port
No.
Symbol
Signal Names
Symbol
Signal Names
Symbol
Signal Names
0
PC1
PC1
PC1
1
PC2
PC2
PC2
2
PC4
PC4
PC4
3
PC8
PC8
PC8
4
PC16
PC16
PC16
5
PC32
Command position
No.
PC32
Command position No.
PC32
6
MODE
Teaching Mode
Command
PC64
7
JISL
Jog/Inching selection
PC128
Command position No.
8
Unavailable
JOG+
+ Jog
Unavailable
9
BKRL
Forced brake release
JOG-
- Jog
RKRL
Forced brake release
10
RMOD
Operation mode
RMOD
Operation mode
RMOD
Operation mode
11
HOME
Return to origin
HOME
Return to origin
HOME
Return to origin
12
*STP
Pause
*STP
Pause
*STP
Pause
13
CSTR
Positioning Start
CSTR/
PWRT
Positioning Start/
Position Data Import
Command
CSTR
Positioning Start
14
RES
Reset
RES
Reset
RES
Reset
PLC Output㸢
ACON Input
15
SON
Servo ON Command
SON
Servo ON Command
SON
Servo ON Command
0
PM1
PM1
PM1
1
PM2
PM2
PM2
2
PM4
PM4
PM4
3
PM8
PM8
PM8
4
PM16
PM16
PM16
5
PM32
Completion position
No.
PM32
Completion position
No.
PM32
6
MOVE
Moving Signal
MOVE
Moving Signal
PM64
7
ZONE1
Zone 1
MODES
Teaching Mode Signal
PM128
Completion position
No.
8
PZONE
Position zone status
PZONE
Position zone status
PZONE
Position zone status
9
RMDS
Operation Mode
Status
RMDS
Operation Mode Status
RMDS
Operation Mode Status
10
HEND
Return to origin end
HEND
Return to origin end
HEND
Return to origin end
11
PEND
Positioning end Signal
PEND/
WEND
Positioning end Signal/
Position Data
Import Completion
PEND
Positioning end Signal
12
SV
Operation preparation
end
SV
Operation preparation end
SV
Operation preparation end
13
*EMGS
Emergency stop
*EMGS
Emergency stop
*EMGS
Emergency stop
14
*ALM
Alarm
*ALM
Alarm
*ALM
Alarm
ACON Output
㸢
PLC Input
15
Unavailable
Unavailable
Unavailable
The symbol with a * mark shows the ON signal in normal condition.
The signals describing as “Unavailable” are not controlled. (ON/OFF is undefined).