IAI America PCON-CFA User Manual
Page 43
3.
ACON-C/CG, PCON-C/CG
CC-Link
37
(* “ON” in the table shows the corresponding bit of “1” and “OFF” shows “0”.)
Signal Type
Bit Symbol
Description
Details
Current
Position
32bits
Data
32-bit Integer with a Symbol
The unit is 0.01mm.
(Example)
Read Value: 000003FF
H
= 1023 (decimal system) = 10.23mm
* When it is read in hexadecimal notation, input the negative
value using a compliment of 2.
3.9 (2)
Command
Current
32bits
Data
32-bit Integer
It shows the current value in the current command.
The unit is mA.
Read Value: 000003FF
H
= 1023 (decimal system) = 1023mA
3.9 (2)
Current
Speed
32bits
Data
32-bit Integer with a Symbol
It shows the current speed.
Positive Figure: Under movement in the opposite direction of home
Negative Figure: Under movement in the home direction
The unit is 0.01mm/sec.
(Example)
Read Value: 000003FF
H
= 1023 (decimal system)
= 10.23mm/sec
* When it is read in hexadecimal notation, input the negative
value using a compliment of 2.
3.9 (2)
Alarm
code
16bits
Data
16-bit Integer
When an alarm is issued, the alarm code is output.
When any alarm is not issued, it is “0
H
”.
Refer to the instruction manual for the controller main body for
the details of the alarms.
3.9 (2)
b15
EMGS Emergency Stop: “ON” for Emergency Stop Status
3.7.7 (2)
b14
PWR Controller Ready: “ON” for Ready
3.7.7 (1)
b13 ZONE2 Zone 2: “ON” for the current position within the zone set range 3.7.7 (12)
b12 ZONE1 Zone 1: “ON” for the current position within the zone set range 3.7.7 (12)
b11
b10
b9
Unavailable
b8
RMDS
Operation Mode Status:
“OFF” for currently “AUTO” mode, “ON” for currently “MANU”
mode
3.7.7 (19)
b7
b6
Unavailable
b5
PSEL Pressing and a Miss: “ON” for pressing and a miss
3.7.7 (23)
b4
SV
Operation Ready: “ON” with Servo ON
3.7.7 (5)
b3
ALM Alarm: “ON” with alarm issue
3.7.7 (3)
b2
MOVE
Movement Signal:
“ON” with Actuator Movement
3.7.7 (9)
b1
HEND
Homing Completion
“ON” with Homing Completion
3.7.7 (6)
P
LC
In
pu
t
Status
Signal
b0
PEND
Positioning Completion Signal:
“ON” with Positioning Completion
3.7.7 (10)