beautypg.com

Set pvc red-pack, Command mode, Description – Avaya Cajun P880 User Manual

Page 86: Syntax, Sample output

background image

1-76

Chapter 1

Avaya P550R/P580/P880/P882 Multiservice Switch ATM Uplink CLI Reference Guide, Version 2.0

set pvc red-pack

Command Mode

Configure

Description

Sets the Red-Pack (random early detection) ID for the specified pvc.

* Note: RED is always disabled and cannot be set for UBR traffic

class PVCs.

Syntax

set pvc red-pack

Table 1-46. Arguments, Parameters, Keywords

Sample Output

The following example sets the red-id of the pvc to 3.

ATM(configure)# set pvc 1-4-101 red-pack 3

Red Pack set successfully for PVC 1-4-101

Name

Definition

pvcID

The identifier for the pvc. It is equal to
<physPort> - <vpi> - <vci>

(e.g., port number 1 with a vpi of 4 and a vci of
101 would have a pvcID of 1-4-101)

redID

The RED ID of the pvc. Range is 1 - 4. Use 0 to
disable RED on this pvc.