Ip setup, Figure 78 – Extron Electronics HDXP Plus Series User Guide User Manual
Page 81
HDXP Plus Series Switchers • Matrix Software
75
IP Setup
The IP Settings/Options window (see figure 78) lets you view and, if connected via the
RS-232 or RS-422 link or if you are logged on via the Ethernet port as an administrator,
editing settings unique to the Ethernet interface. None of the fields on this screen can
be edited while you are logged on as a user. To display the IP Settings/Options window,
select
IP
Options
from the
Tools
drop-down menu.
Figure 78.
IP Setting/Options Window
NOTES:
•
Editing the following fields on the IP Settings/Options screen while connected via
the Ethernet port can immediately disconnect your computer from the switcher:
•
IP
Address
•
Gateway
IP
Address
•
Subnet
Mask
•
Use
DHCP
•
Administration
Password
Extron recommends editing the settings on this screen using the
RS-232 or RS-422 link and protecting the Ethernet access to this screen by
assigning an administrator password to qualified and knowledgeable personnel
only.
•
When the control program is connected to the HDXP via the RS-232 or RS-422
link, the
Administrator
Password
and
User
Password
fields are not masked. If
a password has been inadvertently changed to an unknown value, you can look
up and, if desired, change a password in this window without knowing the current
password.
See