Extron Electronics HDXP Plus Series User Guide User Manual
Page 65
HDXP Plus Series Switchers • Remote Configuration and Control
59
Command
ASCII Command
(Host to Switcher)
Response
(Switcher to Host)
Additional Description
Rooms
Write room outputs
E
X*
,
X#
,...
X#
n
MR
}
Mpr
X*
,
X#
,...
X#
n
]
Assign outputs
X#
through
X#
n
to room
X*
.
NOTES:
•
The maximum number of outputs per room is 16.
•
The maximum number of rooms is 10.
•
An output can be assigned to only one room.
Read room outputs
E
X*
MR
}
Name,
X#
,...
X#
n
]
Show outputs
X#
through
X#
n
assigned to room
X*
.
Example:
E
3MR
}
Class1,01,02,08,09
]
Outputs 1, 2, 8, and 9 are
assigned to room 3, which is
named “Class1.”
Names
Write global preset name
E
X1!,X2#
NG
}
Nmg
X1!,X2#
]
Assign global preset
X1!
the
name
X2#
.
Example:
E
1,Security 1NG
}
Nmg01
,
Security1
]
Name global preset 1
Security 1.
Read global preset name
E
X1!
NG
}
X2#
]
View the name (
X2#
) assigned
to global preset number
X1!
.
Example:
E
2NG
}
Security 2
]
Show the name (Security 2) of
global preset 2.
Write room name
E
X1@,X2#
NR
}
Nmr
X1@,X2#
]
Assign room preset
X1@
the
name
X2#
.
Example:
E
1
,
Classrm 1NR
}
Nmr01
,
Classrm1
]
Name room 1 Classrm 1.
Read room name
E
X1@
NR
}
X2#
]
Write room preset name
E
X1@
*
X*,X2#
NP
}
Nmp
X1@
*
X*,X2#
]
Example:
E
1*3
,
Podium_DVDNP
}
Nmp01*3
,
Podium_DVD
]
Name room 1, preset 3
Podium_DVD.
Read room preset name
E
X1@,X*
NP
}
X1#
]
NOTES:
•
Do not use leading spaces in preset names.
•
If a preset is unassigned,
X2#
is [unassigned].
•
If a global preset is saved, but not yet named, the default name is Preset
X1!
.
•
If a room preset is saved, but not yet named, the default name is Rm
X1@
Prst
X*
.
Write input name
E
X!,X2#
NI
}
Nmi
X!,X2#
]
Assign name
X2#
to input
X!
.
Example:
E
1
,
Podium camNI
}
Nmi1
,
Podium cam
]
Name Input 1 Podium cam.
Read input name
E
X!
NI
}
X2#
]
View the name of input
X!
.
Write output name
E
X#,X2#
NO
}
Nmo
X#,X2#
]
Assign name
X2#
to
output
X#
.
Example:
E
1,Main PJ1NO
}
Nmo1,Main PJ1
]
Name output 1 Main PJ1.
Read output name
E
X#
NO
}
X2#
]
View the name of output
X#
.
NOTE:
X!
= Input number (for ties)
0 – maximum number of inputs for your model (0 = untied)
X#
= Output number
1 – maximum number of outputs for your model
X*
= Room number (for room presets)
1 – 10. Each room can have up to 10 room presets (
X1@
) assigned.
X1!
= Global preset number
00 – 32. 00 = current configuration
X1@
= Room preset number
1 – 10. Each room (
X*
) can have up to 10 presets assigned.
X2#
= Name (for room, room presets,
12 characters maximum for preset names
and global presets)
11 characters maximum for room names
Valid characters are a–z, A–Z, 0–9, " _ : and {space}.