HDXP Plus Series Switchers • Remote Configuration and Control

47

3.

If the password is accepted, the switcher responds with

Login

User

or

Login

Administrator

.

4.

If the password is not accepted, the

Password

prompt reappears.

Number of Connections

An HDXP switcher can have up to 200 simultaneous TCP connections, including all http
and Telnet connections. When the connection limit is reached, the switcher accepts no
new connections until some have been closed. No error message or indication is given
that the connection limit has been reached. To maximize performance, keep the number
of connections low and close unnecessary sockets.

Verbose Mode

The connection to an HDXP switcher can be used to monitor for changes that occur on
the switcher, such as front panel operations and SIS commands from other connections
or a serial port. To receive change notices from the switcher, you must enable verbose
mode 1 or 3 (see

Verbose Mode Commands

on page 66). In verbose mode 1 or 3,

changes are reported in messages that resemble SIS command responses.

Host-to-Switcher Instructions

The HDXP accepts SIS (Simple Instruction Set) commands through the
RS-232/RS-422 and Ethernet ports. SIS commands consist of one or more characters
per command field. They do not require any special characters to begin or end the
command character sequence. Each switcher response to an SIS command ends with
a carriage return and a line feed (CR/LF = ]), which signals the end of the response

character string. A string is one or more characters.

Switcher-Initiated Messages

When a local event such as a front panel operation occurs, the switcher responds
by sending a message to the host. The switcher-initiated messages are listed below
(underlined).
With an RS-232 or RS-422 connection:

(c)

Copyright

20nn,

Extron

Electronics

HDXP

Plus

Series,

Vn.nn,

60-nnn-01

]

With an Internet connection:

(c)

Copyright

20nn,

Extron

Electronics

HDXP

Plus

Series,

Vn.nn

,

60-nnn-01

]

Ddd,

DD

Mmm

YYYY

HH:MM:SS

]

The switcher initiates the copyright message when it is first powered on or when
connection via Internet protocol (IP) is established.

Vn.nn

is the firmware version number,

60

-

nnn

-

01

is the HDXP model part number, and

20nn

is the copyright year.

]

Password:

The switcher initiates the password message immediately after the copyright message
when the controlling system is connected using TCP/IP or Telnet and the switcher is
password protected. This message means that the switcher requires an administrator or
user level password before it will perform the commands entered via this link.

NOTE: The Password prompt dialog box is redisplayed if an incorrect password is

entered.