11

The cable that you use depends on your network speed. The switcher supports
both 10 Mbps (10Base-T — Ethernet) and 100 Mbps (100Base-T — Fast Ethernet),
half-duplex and full-duplex, Ethernet connections.

10Base-T Ethernet requires CAT 3 UTP or STP cable at minimum.

100Base-T Fast Ethernet requires CAT 5e UTP or STP cable at minimum.

RS-232 and RS-422 Remote Connections

g

Remote RS232/RS422 connector — Connect a host device, such as a computer,

touch panel control, or RS-232 capable PDA to the switcher via this 9-pin D
connector for serial RS-232 or RS-422 control.

RS-232 Function

Pin

Function

1
2
3
4
5
6
7
8
9

Tx

Rx

Gnd




Not used
Transmit data
Receive data
Not used
Signal ground
Not used
Not used
Not used
Not used

Tx–

Rx–

Gnd

Rx+

Tx+

Not used
Transmit data (–)
Receive data (–)
Not used
Signal ground
Not used
Receive data (+)
Transmit data (+)
Not used

RS-422

5

1

9

6

RS232 / RS422

REMO

TE

Figure 8.

Remote RS232/RS422 Connector

See the

Remote Configuration and Control

section beginning on page 45 for

definitions of the SIS commands (serial commands to control the switcher via this
connector) and the

Matrix Software

section beginning on page 67 for details on

how to install and use the control software.

NOTE: The switcher can support either an RS-232 or RS-422 serial

communication protocol, and operate at 9600, 19200, 38400, or 115200 baud
rates (see

Selecting the RS-232 or RS-422 Protocol and Baud Rate

on

page 36 to configure the RS232/RS422 port from the front panel).

If desired, connect an MKP 2000 or MKP 3000 remote control panel to the switcher
Remote RS232/RS422 connector (see the MKP 2000 Remote Control Panel User’s
Manual
and the MKP 3000 User’s Manual for details).

RS-232 Config connector (front panel) — On the HDXP 3232 only, an additional
RS-232 port is located on the front panel. A host device can be connected to this
port for serial RS-232 control only. Protocol for the port is:

9600 baud

8 data bits

1 stop bit

No parity

No flow control