51

X2^

= GMT date and time (read) in the format

Www, • DDMmmYYYYHH:MM:SS

Www = name of the day of the week (Mon through Sun)

DD = day of the month (01 through 31)

Mmm = Name of the month (Jan through Dec)

YYYY = year (20nn)

HH = hour (00 through 24)

MM = minutes (00 through 59)

SS = seconds (00 through 59)

• = space

X2&

= IP address (nnn.nnn.nnn.nnn). Leading zeros in each of the four fields are

optional.

X2*

= E-mail event number: 1 – 64

X2(

= Default name (Factory default name consisting of model name plus the

last three character pairs of MAC address)
Example: HDXP-Plus-Serie-00-2E-C7

X3)

= Password (12 characters maximum)

NOTE: The following characters are invalid in the password:

~ , + @ = [ ] { } ‘ < > " ; : \ | ? and {space}.

X3!

= Connection security level

0 = anonymous
1 – 10 = Extended security levels 1 through 10
11 = User level
12 = Administrator level

The response is returned as two digits with a leading zero if needed.

X3@

=

E-mail user name (e-mail name for the HDXP) (240 characters maximum)

X3#

= E-mail address: Acceptable e-mail address format (for example, xxxxx@xxx.com)

X3$

= Hardware (MAC) address (nn-nn-nn-nn)

The media access code (MAC) or hardware address is an identification code for the unit,
consisting of six pairs of alphanumeric characters. This address cannot be changed.

X3%

= Number of open connections (0 – 255)

X3&

= GMT date (MM/DD/YYHH:MM:SS)

X3*

= Mail domain name (Standard domain name conventions apply.

Example: extron.com)

X3(

= GMT offset (-12.0 through +14.0 hours and minutes removed from

Greenwich Mean Time)

X4)

= Daylight Savings time

0 = Daylight savings time off or ignored
1 = Daylight savings time on (used in the northern hemisphere [USA]

and parts of Europe and Brazil)

X4!

= E-mail account number (65 through 72)

X4@

= Notify when?

0 = No response
1 = Fail or missing
2 = Fixed and restored
3 = Both 1 and 2

X4#

= Notification selections

HDXP 3216 and 3232: 01 – 32 = Inputs 1 through 32

HDXP 1616: 01 – 16 = Inputs 1 through 16

Power supply: 98

X4$

= Notify status for reading (16-digit number). For each digit,

0 = Do not notify
1 = Notify

X4%

= DHCP status

0 = Off
1 = On