Extron Electronics HDXP Plus Series User Guide User Manual
Page 57

HDXP Plus Series Switchers • Remote Configuration and Control
51
X2^
= GMT date and time (read) in the format
Www, • DD • Mmm • YYYY • HH:MM:SS
Www = name of the day of the week (Mon through Sun)
DD = day of the month (01 through 31)
Mmm = Name of the month (Jan through Dec)
YYYY = year (20nn)
HH = hour (00 through 24)
MM = minutes (00 through 59)
SS = seconds (00 through 59)
• = space
X2&
= IP address (nnn.nnn.nnn.nnn). Leading zeros in each of the four fields are
optional.
X2*
= E-mail event number: 1 – 64
X2(
= Default name (Factory default name consisting of model name plus the
last three character pairs of MAC address)
Example: HDXP-Plus-Serie-00-2E-C7
X3)
= Password (12 characters maximum)
NOTE: The following characters are invalid in the password:
~ , + @ = [ ] { } ‘ < > " ; : \ | ? and {space}.
X3!
= Connection security level
0 = anonymous
1 – 10 = Extended security levels 1 through 10
11 = User level
12 = Administrator level
The response is returned as two digits with a leading zero if needed.
X3@
=
E-mail user name (e-mail name for the HDXP) (240 characters maximum)
X3#
= E-mail address: Acceptable e-mail address format (for example, xxxxx@xxx.com)
X3$
= Hardware (MAC) address (nn-nn-nn-nn)
The media access code (MAC) or hardware address is an identification code for the unit,
consisting of six pairs of alphanumeric characters. This address cannot be changed.
X3%
= Number of open connections (0 – 255)
X3&
= GMT date (MM/DD/YY • HH:MM:SS)
X3*
= Mail domain name (Standard domain name conventions apply.
Example: extron.com)
X3(
= GMT offset (-12.0 through +14.0 hours and minutes removed from
Greenwich Mean Time)
X4)
= Daylight Savings time
0 = Daylight savings time off or ignored
1 = Daylight savings time on (used in the northern hemisphere [USA]
and parts of Europe and Brazil)
X4!
= E-mail account number (65 through 72)
X4@
= Notify when?
0 = No response
1 = Fail or missing
2 = Fixed and restored
3 = Both 1 and 2
X4#
= Notification selections
HDXP 3216 and 3232: 01 – 32 = Inputs 1 through 32
HDXP 1616: 01 – 16 = Inputs 1 through 16
Power supply: 98
X4$
= Notify status for reading (16-digit number). For each digit,
0 = Do not notify
1 = Notify
X4%
= DHCP status
0 = Off
1 = On