Texas Instruments TMS320C2XX User Manual
Page 502
Task-Specific Program Code
C-17
Program Examples
Example C–11. Testing and Using Automatic Baud-Rate Detection on
Asynchronous Serial Port (autobaud.asm) (Continued)
uart:
setc
xf
in
68h,iosr
; load input status from iosr
bit
68h,1
; check if auto baud bit is set
bcnd
rcv,ntc
; branch normal receive
splk
#4fffh,67h
; clear ADC
out
67h,iosr
splk
#0e080h,67h
out
67h, aspcr
; Disable CAD bit/auto baud
rcv:
in
68h,iosr
; check for DR bit
bit
68h,7
; bit 8 in the data
bcnd
skip,ntc
; IF DR=0 no echo, return
in
*,adtr
; read and save at 300h
out
*+,adtr
; echo
mar
*,ar0
banz
skip,ar1
; check if size=0, and reload
lar
ar1,#rxbuf
lar
ar0,#size
skip:
splk
#0020h,ifr
; Clear ifr
clrc
intm
ret
inpt1:
ret
inpt23:
ret
timer:
ret
codtx:
ret
codrx:
ret
.end
; Assembler module end directive
; –optional