Texas Instruments TMS320C2XX User Manual
Page 480
Instruction Set Comparison Table
B-31
TMS320C1x/C2x/C2xx/C5x Instruction Set Comparison
Syntax
Description
5x
2xx
2x
1x
SHM
√
√
Set Hold Mode
Set the HM status bit to 1.
SMMR
dma, #lk
SMMR {
ind}, #lk [, next ARP]
√
√
Store Memory-Mapped Register
Store the memory-mapped register value, pointed at
by the 7 LSBs of the data-memory address, into the
long immediate addressed data-memory location. The
9 MSBs of the data-memory address of the memory-
mapped register are cleared, regardless of the current
value of DP or the upper 9 bits of AR(ARP).
SOVM
√
√
√
√
Set Overflow Mode
Set the OVM status bit to 1; this enables overflow
mode. (The ROVM instruction clears OVM.)
SPAC
√
√
√
√
Subtract P Register From Accumulator
Subtract the contents of the P register from the
contents of the accumulator.
TMS320C2x, TMS320C2xx, and TMS320C5x de-
vices: Before the subtraction, shift the contents of the
P register as specified by the PM status bits.
SPH
dma
SPH {
ind} [, next ARP]
√
√
√
√
√
√
Store High P Register
Store the high-order bits of the P register (shifted as
specified by the PM status bits) at the addressed data-
memory location.
SPL
dma
SPL {
ind} [, next ARP]
√
√
√
√
√
√
Store Low P Register
Store the low-order bits of the P register (shifted as
specified by the PM status bits) at the addressed data-
memory location.
SPLK #
lk, dma
SPLK #
lk, {ind} [, next ARP]
√
√
√
Store Parallel Long Immediate
Write a full 16-bit pattern into a memory location. The
parallel logic unit (PLU) supports this bit manipulation
independently of the ALU, so the accumulator is unaf-
fected.
SPM
2-bit constant
√
√
√
Set P Register Output Shift Mode
Copy a 2-bit immediate value into the PM field of ST1.
This controls shifting of the P register as shown below:
PM = 00
2
Multiplier output is not shifted.
PM = 01
2
Multiplier output is left shifted one place
and zero filled.
PM = 10
2
Multiplier output is left shifted four places
and zero filled.
PM = 11
2
Multiplier output is right shifted six places
and sign extended; the LSBs are lost.