Siemens S5-135U/155U User Manual
Simatic
Table of contents
Document Outline
- Title
- Contents
- 1 Notes on Using this Manual andontheCESymbol
- 2 Centralized and Distributed Configuration of a Programmable Controller
- 3 Installation Guidelines
- 3.1 Principles of Installation of Systems for EMC
- 3.1.1 Overview of Possible Types of Interference
- 3.1.2 The Most Important Basic Rules for Ensuring EMC
- 3.2 Installation of Programmable Controllers for EMC
- 3.2.1 Basic Rules for Assembling and Grounding the Inactive Metal Parts
- 3.2.2 Example of Cabinet Assembly for EMC
- 4 Central Controllers and Expansion Units Power Supply Units
- 4.1 S5-135U/155U Central Controller
- 4.1.1 Technical Description
- 4.1.2 Installation
- 4.1.3 Startup
- 4.1.4 Repair Guidelines
- 4.1.5 Technical Specifications
- 4.2 Expansion Units
- 4.2.1 Technical Description of the Expansion Units
- 4.2.2 Installing the Expansion Units
- 4.2.3 Technical Specifications of the Expansion Units
- 4.3 Power Supply Units
- 4.3.1 Product Overview
- 4.3.2 Setting and Connecting the Power Supply Unit
- 4.3.3 Fault Indications/Fault Diagnostics
- 4.3.4 Maintenance and Repairs
- 4.3.5 Description of Internal Sequences in the Power Supply Unit
- 4.3.6 Technical Specifications of the Power Supply Units
- 4.4 6ES5 955-3NA12 Power Supply Unit
- 4.4.1 Technical Description
- 4.4.2 Setting the Power Supply Unit
- 4.4.3 Installation
- 4.4.4 Operation
- 4.4.5 Maintenance
- 4.4.6 Technical Specifications
- 4.5 Fan Submodules
- 4.5.1 Technical Description
- 4.5.2 Setting and Connecting the Fan Submodule
- 4.5.3 Technical Specifications
- 5 CPUs, Memory Cards, Memory Submodules, Interface Submodules
- 5.1 CPU 948B -3UA13 or CPU 948B -3UA23
- 5.1.1 Technical Description
- 5.1.2 Installation and Startup
- 5.1.3 Interfaces of the CPU 948
- 5.1.4 Technical Specifications
- 5.2 CPU 948
- 5.2.1 Technical Description
- 5.2.2 Installation and Startup
- 5.2.3 Interfaces of the CPU 948
- 5.2.4 Technical Specifications
- 5.3 CPU 928B -3UB21
- 5.3.1 Technical Description
- 5.3.2 Installation and Startup
- 5.3.3 Technical Specifications
- 5.4 CPU 928B
- 5.4.1 Technical Description
- 5.4.2 Installation and Startup
- 5.4.3 Technical Specifications
- 5.5 CPU 928 -3UA21
- 5.5.1 Technical Description
- 5.5.2 Installation and Startup
- 5.5.3 Technical Specifications
- 5.6 CPU 928
- 5.6.1 Technical Description
- 5.6.2 Installation and Startup
- 5.6.3 Technical Specifications
- 5.7 CPU 922
- 5.7.1 Technical Description
- 5.7.2 Installation and Startup
- 5.7.3 Technical Specifications
- 5.8 374 Flash EPROM Cards
- 5.8.1 Technical Description
- 5.8.2 Notes on Operation
- 5.8.3 Technical Specifications
- 5.9 376 Memory Submodules
- 5.9.1 Technical Description
- 5.9.2 Notes on Operation
- 5.9.3 Technical Specifications
- 5.10 377 Memory Submodules
- 5.10.1 Technical Description
- 5.10.2 Notes on Operation
- 5.10.3 RAM Submodules with Battery Backup
- 5.10.4 Technical Specifications
- 5.11 Interface Submodules
- 5.11.1 Installing and Removing the Interface Submodules
- 5.11.2 PG Submodule
- 5.11.3 V.24 Submodule
- 5.11.4 TTY Submodule
- 5.11.5 RS422 A/485 Submodule
- 5.11.6 SINEC L1 Submodule
- 5.11.7 Technical Specifications of the Interface Submodules
- 6 Multiprocessor Operation/Coordinators
- 6.1 Introduction
- 6.2 Starting the Multiprocessor Operation
- 6.3 Coordinator Modes
- 6.4 923A Coordinator Module
- 6.4.1 Technical Description
- 6.4.2 Settings on the Coordinator
- 6.5 923C Coordinator Module
- 6.5.1 Technical Description
- 6.5.2 Settings on the Coordinator
- 6.6 Technical Specifications of the Coordinators
- 7 Interface Modules
- 7.1 The 300 and 312 Interface Modules
- 7.1.1 Indicators and Controls
- 7.1.2 Modes/Jumper Assignments of the IM 300
- M1
- P1
- 7.2 The 301 and 310 Interface Modules
- 7.2.1 Indicators and Controls
- 7.2.2 Modes/Jumper Assignments of the IM 301
- 7.3 The 304 and 314 Interface Modules
- 7.3.1 Indicators and Controls
- 7.3.2 Modes/Jumper Assignments of the IM 304
- 7.3.3 Modes/Jumper Assignments of the IM 314
- 7.4 Technical Specifications
- 7.4.1 6ES5 721 Connecting Cable
- 7.4.2 6ES5 7602 Terminator
- 8 Digital Input/Output Modules
- 8.1 Technical Description
- 8.1.1 Design
- 8.1.2 Function of the Enable Inputs
- 8.1.3 Special Features of the 432 Digital Input Module
- 8.1.4 Special Features of the DI/DQ 482
- 8.2 Installation and Startup
- 8.2.1 Setting the Module Address
- 8.2.2 Removing and Inserting Modules
- 8.2.3 Marking of Modules
- 8.2.4 Connecting the Signal Lines
- 8.2.5 Connection of Outputs in Parallel and Switching On the Load via a Contact
- 8.2.6 Short-Circuit Protection and Fusing
- 8.2.7 Arc-Quenching for Inductive Loads
- 8.3 Common Technical Specifications
- 8.4 Specification Sheets for the Modules
- 8.4.1 6ES5 420-4UA13/4UA14 Digital Input Module
- 8.4.2 6ES5 430-4UA13/4UA14 Digital Input Module
- 8.4.3 6ES5 431-4UA12 Digital Input Module
- 8.4.4 6ES5 432-4UA12 Digital Input Module
- 8.4.5 6ES5 434-4UA12 Digital Input Module
- 8.4.6 6ES5 435-4UA12 Digital Input Module
- 8.4.7 6ES5 436-4UA12 Digital Input Module
- 8.4.8 6ES5 436-4UB12 Digital Input Module
- 8.4.9 6ES5 441-4UA13/4UA14 Digital Output Module
- 8.4.10 6ES5 451-4UA13/4UA14 Digital Output Module
- 8.4.11 6ES5 453-4UA12 Digital Output Module
- 8.4.12 6ES5 454-4UA13/4UA14 Digital Output Module
- 8.4.13 6ES5 455-4UA12 Digital Output Module
- 8.4.14 6ES5 456-4UA12 Digital Output Module
- 8.4.15 6ES5 456-4UB12 Digital Output Module
- 8.4.16 6ES5 457-4UA12 Digital Output Module
- 8.4.17 6ES5 458-4UA12 Digital Output Module
- 8.4.18 6ES5 458-4UC11 Digital Output Module
- 8.4.19 6ES5 482-4UA11 Digital Input/Output Module
- 9 Analog Input/Output Modules
- 9.1 Technical Description
- 9.2 Common Technical Specifications
- 9.3 The 460 Analog Input Module
- 9.3.1 Design
- 9.3.2 Function of the Enable Input
- 9.3.3 Special Features of the 460 Analog Input Module
- 9.3.4 Setting the Module Address
- 9.3.5 Removing and Inserting Modules
- 9.3.6 Marking of Modules and Front Connectors
- 9.3.7 Connecting the Signal Lines
- 9.3.8 Connection of Sensors
- 9.3.9 Connecting a Compensating Box for Thermal E.M.F. Measurement
- 9.3.10 Connecting Resistance Thermometers in the Standard Pt 100 Range
- 9.3.11 Connecting Resistance Thermometers in the Extended Pt 100 Range
- 9.3.12 Broken Wire Signal
- 9.3.13 Connecting Transducers
- 9.3.14 Measured-Value Representation
- 9.3.15 Technical Specifications
- 9.4 The 463 Analog Input Module
- 9.4.1 Design
- 9.4.2 Function of the Enable Input
- 9.4.3 Special Features of the 463 Analog Input Module
- 9.4.4 Setting the Module Address
- 9.4.5 Removing and Inserting Modules
- 9.4.6 Marking of Modules and Front Connectors
- 9.4.7 Connecting the Signal Lines
- 9.4.8 Measured-Value Representation
- 9.4.9 Technical Specifications
- 9.5 The 465 Analog Input Module
- 9.5.1 Design
- 9.5.2 Function of the Enable Input
- 9.5.3 Special Features of the 465 Analog Input Module
- 9.5.4 Setting the Module Address
- 9.5.5 Removing and Inserting Modules
- 9.5.6 Marking of Modules and Front Connectors
- 9.5.7 Connecting the Signal Lines
- 9.5.8 Connecting a Compensating Box for Thermal E.M.F. Measurement
- 9.5.9 Connecting Resistance Thermometers to the 465 Analog Input Module
- 9.5.10 Broken Wire Signal for Resistance Thermometers
- 9.5.11 Connecting Transducers
- 9.5.12 Measured-Value Representation
- 9.5.13 Technical Specifications
- 9.6 The 466 Analog Input Module
- 9.6.1 Design
- 9.6.2 Special Features of the 466 Analog Input Module
- 9.6.3 Startup
- 9.6.4 Removing and Inserting Modules
- 9.6.5 Marking of Modules and Front Connectors
- 9.6.6 Connecting the Signal Lines
- 9.6.7 Connecting Sensors to the 466 Analog Input Module
- 9.6.8 Measured-Value Representation
- 9.6.9 Technical Specifications
- 9.7 The 470 Analog Output Module
- 9.7.1 Design
- 9.7.2 Function of the Enable Input
- 9.7.3 Special Features of the 470 Analog Output Module
- 9.7.4 Setting the Module Address
- 9.7.5 Removing and Inserting Modules
- 9.7.6 Marking of Modules and Front Connectors
- 9.7.7 Connecting the Signal Lines
- 9.7.8 Connecting Loads to the 470 Analog Output Module
- 9.7.9 Measured-Value Representation
- 9.7.10 Technical Specifications
- 10 Monitoring Module
- 10.1 Application
- 10.1.1 Design
- 10.1.2 Mode of Operation
- 10.1.3 Block Diagram
- 10.1.4 Fault Detection
- 10.1.5 Resetting
- 10.2 Installation
- 10.2.1 Possible Configurations
- 10.2.2 Removing and Inserting
- 10.2.3 Connecting the RESET Input
- 10.2.4 Switch Positions of the Relay Contact
- 10.2.5 Installation Guidelines
- 10.3 Operation
- 10.3.1 Addressing
- 10.3.2 Setting the Address Switches S1, S2, S3, S4
- 10.3.3 Setting the Switch S5
- 10.4 Technical Specifications
- 10.5 Address Table
- 11 Connector Assignments
- A Appendix
- B Guidelines for Handling Electrostatically Sensitive Devices (ESD)
- Index
- Remarks Form