Table 36: fru power requirements – Juniper Networks MX480 User Manual
Page 314

NOTE:
The power for the cooling system comes from a different tap on the
power supply, reserved for the cooling system only. The cooling system power
requirement does not need to be deducted from the output power budget
of the power supply.
Table 36: FRU Power Requirements
Maximum Power Requirement
Part Number
Component
Switch Control Boards (SCBs)
150 W
SCB-MX960 (applies to
MX240, MX480, and
MX960)
Switch Control Board
150 W
SCBE-MX (applies to
MX240, MX480, and
MX960)
Enhanced MX Switch
Control Board
Routing Engines
90 W
RE-S-1300-2048
RE-S-1800X2-8G
RE-S-1800X4-8G
RE-S-1800X2-16G
RE-S-1800X4-16G
RE-S-2000-4096
Routing Engines
MPCs
440 W at 55 degrees C ambient
423 W at 25 degrees C ambient
MPC-3D-16XGE-SFPP
MPC-3D-16XGE-SFPP-R-B
16x10GE MPC
165 W
With MICs and optics:
239 W at 55 degrees C
227 W at 40 degrees C
219 W at 25 degrees C
MX-MPC1-3D
MX-MPC1E-3D
MPC1
175 W
With MICs and optics:
249 W at 55 degrees C
237 W at 40 degrees C
228 W at 25 degrees C
MX-MPC1-3D-Q
MX-MPC1E-3D-Q
MPC1 Q
Copyright © 2013, Juniper Networks, Inc.
290
MX480 3D Universal Edge Router Hardware Guide