Maintaining mx480 fpcs – Juniper Networks MX480 User Manual
Page 156

Start time: 2007-07-10 12:28:42 PDT
Uptime: 1 hour, 33 minutes, 43 seconds
Max Power Consumption 333 Watts
•
Issue the CLI
show chassis fpc pic-status
command. The DPC slots are numbered
0
through
5
, bottom to top:
user@host>
show chassis fpc pic-status
Slot 0 Online DPCE 4x 10GE R
PIC 0 Online 1x 10GE(LAN/WAN)
PIC 1 Online 1x 10GE(LAN/WAN)
PIC 2 Online 1x 10GE(LAN/WAN)
PIC 3 Online 1x 10GE(LAN/WAN)
Slot 1 Online DPCE 40x 1GE R
PIC 0 Online 10x 1GE(LAN)
PIC 1 Online 10x 1GE(LAN)
PIC 2 Online 10x 1GE(LAN)
PIC 3 Online 10x 1GE(LAN)
Slot 2 Online DPCE 40x 1GE R
PIC 0 Online 10x 1GE(LAN)
PIC 1 Online 10x 1GE(LAN)
PIC 2 Online 10x 1GE(LAN)
PIC 3 Online 10x 1GE(LAN)
Slot 5 Online DPC 4x 10GE R
PIC 0 Online 1x 10GE(LAN/WAN)
PIC 1 Online 1x 10GE(LAN/WAN)
PIC 2 Online 1x 10GE(LAN/WAN)
PIC 3 Online 1x 10GE(LAN/WAN)
For further description of the output from the command, see the Junos OS Operational
Mode Commands.
Related
Documentation
MX480 Chassis Description on page 7
•
•
DPC and MPC LEDs on the MX480 Craft Interface on page 39
Maintaining MX480 FPCs
Purpose
The MX480 router can have up to three Flexible PIC Concentrators (FPCs) installed
horizontally in the front of the chassis. For optimum router performance, verify the
condition of the FPC.
Action
On a regular basis:
•
Check the LEDs on the craft interface directly above the FPC. The green LED labeled
OK
lights steadily when an FPC is functioning normally.
•
Check the
OK/FAIL
LED on the FPC. If the FPC detects a failure, the FPC sends an alarm
message to the Routing Engine.
•
Issue the CLI
show chassis fpc
command to check the status of the installed FPC. As
shown in the sample output, the value
Online
in the column labeled
State
indicates
that the FPC is functioning normally:
user@host>
show chassis fpc
Copyright © 2013, Juniper Networks, Inc.
132