Juniper Networks MX480 User Manual
Page 181

Temp CPU Utilization (%) Memory Utilization (%)
Slot State (C) Total Interrupt DRAM (MB) Heap Buffer
0 Online 36 3 0 2048 14 13
1 Online 40 5 0 2048 26 13
2 Online 41 6 0 1024 7 43
3 Online 43 5 0 1024 16 57
4 Online 24 3 0 1024 13 21
5 Empty
NOTE:
The
show chassis fpc
command displays the status of the MPCs.
For more detailed output, add the
detail
option. The following example does not specify
a slot number, which is optional:
user@host>
show chassis fpc detail
Slot 0 information:
State Online
Temperature 33 degrees C / 91 degrees F
Total CPU DRAM 1024 MB
Total RLDRAM 256 MB
Total DDR DRAM 4096 MB
Start time: 2009-12-22 12:26:54 PST
Uptime: 6 days, 3 hours, 8 minutes, 51 seconds
Max Power Consumption 330 Watts
Slot 1 information:
State Online
Temperature 32 degrees C / 89 degrees F
Total CPU DRAM 1024 MB
Total RLDRAM 256 MB
Total DDR DRAM 4096 MB
Start time: 2009-12-22 12:26:54 PST
Uptime: 6 days, 3 hours, 8 minutes, 51 seconds
Max Power Consumption 365 Watts
Slot 2 information:
State Online
Temperature 41 degrees C / 105 degrees F
Total CPU DRAM 1024 MB
Total RLDRAM 128 MB
Total DDR DRAM 2048 MB
Start time: 2009-12-22 12:26:46 PST
Uptime: 6 days, 3 hours, 8 minutes, 59 seconds
Max Power Consumption 265 Watts
Slot 3 information:
State Online
Temperature 36 degrees C / 96 degrees F
Total CPU DRAM 2048 MB
Total RLDRAM 806 MB
Total DDR DRAM 2632 MB
Start time: 2009-12-22 12:27:04 PST
Uptime: 6 days, 3 hours, 8 minutes, 41 seconds
Max Power Consumption 450 Watts
Slot 4 information:
State Online
Temperature 40 degrees C / 104 degrees F
157
Copyright © 2013, Juniper Networks, Inc.
Chapter 13: Troubleshooting MX480 Hardware Components