Replacing an mx480 fpc, Removing an mx480 fpc, Figure 98: attaching a cable to a dpc – Juniper Networks MX480 User Manual
Page 218: Figure 98 on
![background image](/manuals/134693/218/background.png)
Figure 98: Attaching a Cable to a DPC
Related
Documentation
Preventing Electrostatic Discharge Damage to an MX480 Router on page 248
•
•
MX480 Dense Port Concentrator (DPC) Description on page 10
•
MX480 Dense Port Concentrator (DPC) LEDs on page 12
•
Troubleshooting the MX480 DPCs on page 152
•
Maintaining MX480 DPCs on page 130
Replacing an MX480 FPC
1.
Removing an MX480 FPC on page 194
2.
Installing an MX480 FPC on page 197
Removing an MX480 FPC
When you remove an FPC, the router continues to function, although the PIC interfaces
installed on the FPC being removed no longer function.
An FPC takes up two DPC slots on the MX480 router. Up to three FPCs can be installed
horizontally in the front of the MX480 router. The FPCs are hot-insertable and
hot-removable. An empty FPC3 weighs 14 lb (6.5 kg). A fully configured FPC can weigh
up to 18 lb (8.2 kg). Be prepared to accept its full weight.
To remove an FPC (see
):
1.
Have ready a replacement FPC or FPC blank panel and an antistatic mat for the FPC.
Also have ready rubber safety caps for each PIC using an optical interface on the FPC
that you are removing.
2.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect
the strap to one of the ESD points on the chassis.
3.
Label the cables connected to each PIC on the FPC so that you can later reconnect
the cables to the correct PICs.