Figure 114: installing an as msc – Juniper Networks MX480 User Manual
Page 243

CAUTION:
Slide the AS MSC straight into the slot to avoid damaging the
components on the bottom of the AS MSC.
3.
Use one of the following methods to bring the AS MSC online:
•
Press the AS MSC offline/online button until the LED light turns green.
•
Issue the following CLI command:
user@host>
request chassis pic fpc-slot fpc-slot pic-slot pic-slot online
For more information about the command, see the Junos OS Operational Mode
Commands.
The normal functioning status LED confirms that the AS MSC is online. You can also
verify correct AS MSC functioning by issuing the
show chassis fpc pic-status
.
Figure 114: Installing an AS MSC
g006674
Related
Documentation
Preventing Electrostatic Discharge Damage to an MX480 Router on page 248
•
•
Replacing an MX480 AS MLC on page 214
•
MX480 Application Services Modular Storage Card Description on page 23