For rack-mount installation – Juniper Networks SRX 210 User Manual
Page 74
Install the device as appropriate for your site using one of the following procedures:
•
•
Installing the SRX210 Services Gateway in a Rack on page 59
•
Installing the SRX210 Services Gateway on a Desk on page 62
•
Installing the SRX210 Services Gateway on a Wall on page 63
Adjusting the Power Supply Adapter Tray for the SRX210 Services Gateway for Rack-Mount
Installation
This topic provides details on the power supply adapters provided with different models
of the SRX210 Services Gateway and the procedure for adjusting the power supply
adapter tray to hold the power supply adapter.
The following power supply adapters are provided with the SRX210 Services Gateway:
•
60-watt power supply adapter for the SRX210 Services Gateway Low Memory and
High Memory models
•
150-watt power supply adapter for the SRX210 Services Gateway with PoE
To adjust the power supply adapter tray:
•
To accommodate the 60-watt power supply, use the two 420–028535 screws to
attach the adapter stopper brackets at the point on the chassis marked B.
shows the adjustments to the power supply adapter tray required
for the 60-watt power supply.
Figure 12: Adjusting the Power Supply Adapter Tray to Accommodate the
60-Watt Power Supply
1.
Location for the adapter stopper brackets in the power supply adapter tray
2.
Fully configured power supply adapter tray
•
To accommodate the 150-watt power supply, use the 420–028535 screw to attach
the adapter stopper bracket at the point on the chassis marked A.
Copyright © 2013, Juniper Networks, Inc.
58
SRX210 Services Gateway Hardware Guide