Juniper Networks SRX 210 User Manual
Page 123

Table 38: SRX210 Services Gateway Chassis Alarm Conditions and
Corrective Actions (continued)
Alarm
Severity
Action
Alarm Condition
Component
Amber
(minor)
•
Check the room temperature. See
Services Gateway Specifications” on
page 7
•
Check the airflow. See
Guidelines for Installing the SRX210
Services Gateway” on page 39
.
•
Check the fans. See
Gateway Cooling System” on page 18
.
If you must replace a fan, contact Juniper
Networks Technical Assistance Center
(JTAC). See
Assistance Center” on page 110
The services
gateway chassis
temperature or
chassis is too warm.
Hardware
components
on the
services
gateway
Red
(major)
Use the CLI command
show chassis
environment
to determine whether the fan is
functioning normally.
If the fan has failed, contact JTAC. See
“Juniper Networks Technical Assistance
Center” on page 110
The services
gateway fan has
failed.
Red
(major)
The services gateway shuts down
automatically in 4 minutes.
The services
gateway
temperature is too
high, either because
of an internal
overheating
condition or
because the
maximum
recommended
room temperature
has been exceeded.
Related
Documentation
Monitoring the SRX210 Services Gateway Chassis Using the CLI on page 101
•
•
Monitoring the SRX210 Services Gateway Components Using LEDs on page 103
•
Monitoring the SRX210 Services Gateway Power System on page 108
•
Using the Reset Config Button on the SRX210 Services Gateway on page 109
•
Changing the Reset Config Button Behavior on the SRX210 Services Gateway on page 110
•
Juniper Networks Technical Assistance Center on page 110