beautypg.com

Juniper Networks SRX 210 User Manual

Page 123

background image

Table 38: SRX210 Services Gateway Chassis Alarm Conditions and
Corrective Actions (continued)

Alarm
Severity

Action

Alarm Condition

Component

Amber
(minor)

Check the room temperature. See

“SRX210

Services Gateway Specifications” on
page 7

.

Check the airflow. See

“General Site

Guidelines for Installing the SRX210
Services Gateway” on page 39

.

Check the fans. See

“SRX210 Services

Gateway Cooling System” on page 18

.

If you must replace a fan, contact Juniper
Networks Technical Assistance Center
(JTAC). See

“Juniper Networks Technical

Assistance Center” on page 110

.

The services
gateway chassis
temperature or
chassis is too warm.

Hardware
components
on the
services
gateway

Red
(major)

Use the CLI command

show chassis

environment

to determine whether the fan is

functioning normally.

If the fan has failed, contact JTAC. See

“Juniper Networks Technical Assistance
Center” on page 110

.

The services
gateway fan has
failed.

Red
(major)

The services gateway shuts down
automatically in 4 minutes.

The services
gateway
temperature is too
high, either because
of an internal
overheating
condition or
because the
maximum
recommended
room temperature
has been exceeded.

Related

Documentation

Monitoring the SRX210 Services Gateway Chassis Using the CLI on page 101

Monitoring the SRX210 Services Gateway Components Using LEDs on page 103

Monitoring the SRX210 Services Gateway Power System on page 108

Using the Reset Config Button on the SRX210 Services Gateway on page 109

Changing the Reset Config Button Behavior on the SRX210 Services Gateway on page 110

Juniper Networks Technical Assistance Center on page 110

107

Copyright © 2013, Juniper Networks, Inc.

Chapter 17: Monitoring the SRX210 Services Gateway