beautypg.com

3 error reporting, Rting (section 5.3) – Hitachi TAGMASTORE MK-90RD011-25 User Manual

Page 361

background image

Hitachi Command Control Interface (CCI) User and Reference Guide

343

5.3 Error Reporting

Table 5.2 lists and describes the HORCM system log messages and provides guidelines for
resolving the error conditions. Table 5.3 lists and describes the command error messages and
their return values and also provides guidelines for resolving the error conditions. Table 5.4
and Table 5.5 list the generic error codes. Table 5.6 lists the specific error codes.

Table 5.2

System Log Messages

Message ID

Condition

Cause

Recommended Action

HORCM_001 The HORCM log file cannot be

opened.

The file cannot be created in the

HORCM directory.

Create space on the disk on which the root

directory resides.

HORCM_002 The HORCM trace file cannot be

opened.

The file cannot be created in the

HORCM directory.

Create space on the disk on which the root

directory resides.

HORCM_003 The HORCM daemon process

cannot create a child process due to

an error.

HORCM daemon attempted to

create more processes than the

maximum allowable number.

Terminate unnecessary programs or daemon

processes running simultaneously.

HORCM_004 HORCM assertion failed, resulting in

a fatal internal error in the HORCM.

An internal error which could not be

identified by the HORCM occurred.

Restart the system, and call the Hitachi Data

Systems support center.

HORCM_005 The CCI software failed to create

the end point for remote

communication.

HORCM failed to create a socket, or

an error exists in the HORCM

configuration file ($HORCM_CONF).

Refer to the HORCM startup log to identify

the cause of the error.

HORCM_006 HORCM memory allocation failed.

HORCM memory could not be

secured.

Increase the system virtual memory, or close

any unnecessary programs.

HORCM_007 An error exists in the HORCM setup

file.

An error exists in the HORCM setup

file.

Refer to the startup log and reset the

parameters.

HORCM_008 HORCM configuration file

parameters could not be read.

An error exists in the format or

parameters of the HORCM

configuration file ($HORCM_CONF).

Refer to the HORCM startup log to identify

the cause of the error.

HORCM_009 HORC/HOMRCF connection to the

CCI software failed.

System devices are improperly

connected, or an error exists in the

HORCM configuration file.

Refer to the HORCM startup log to identify

the cause of the error.

HORCM_101 HORC/HOMRCF

and

the

CCI

software communication fails.

A system I/O error occurred or an

error exists in the HORCM

configuration file ($HORCM_CONF).

Refer to the HORCM startup log to identify

the cause of the error.

HORCM_102 The volume is suspended.

The pair status was suspended due

to code XXXX.

Call the Hitachi Data Systems support center.

HORCM_103 Detected a validation check error on

this volume (xxxx unit#x,ldev#x) :

CfEC=n, MNEC=n, SCEC=n,

BNEC=n

A validation error occurs on the

database volume, or validation

parameters for this volume are

illegal.

Please confirm the following items, and use

raidvchkdsp -v command for verifying

the validation parameters.
(1) Check if the block size (-vs ) is an

appropriate size.

(2) Check if the type for checking (-vt )

is an appropriate type.

(3) Check if the data validations are disabled

for LVM configuration changes.

(4) Check if the data validations are not used

based on file system.

(5) Check if the redo log and data file are

separated among the volumes.