beautypg.com

Hitachi TAGMASTORE MK-90RD011-25 User Manual

Page 249

background image

Hitachi Command Control Interface (CCI) User and Reference Guide

231

# raidscan -p cl1-r
Port#, TargetID#, Lun# Num(LDEV#...) P/S,

Status, Fence, LDEV#, P-Seq# P-LDEV#

CL1-R,

15,

7

5(100,101...)

P-VOL

PAIR

NEVER

100,

5678

200

CL1-R,

15,

6

5(200,201...)

SMPL

----

----

----

----


# raidscan -p cl1-r -f
Port#, TargetID#,

Lun# Num(LDEV#...) P/S, Status,

Fence, LDEV#, Vol.Type

CL1-R,

15,

7

5(100,101...)

P-VOL

PAIR

NEVER

100,

OPEN-3

CL1-R,

15,

6

5(200,201...)

SMPL

----

----

----

OPEN-3


# raidscan -pd /dev/rdsk/c0t15/d7 -fg
Port#, TargetID#,

Lun# Num(LDEV#...) P/S, Status,

Fence, LDEV#, Group

CL1-R,

15,

7

5(100,101...)

P-VOL

PAIR

NEVER

100,

oradb

CL1-R,

15,

6

5(200,201...)

SMPL

----

----

----

oradb1

Specified device is LDEV# 0100.

Figure 4.27 Raidscan Command Examples for SCSI Ports

# raidscan -p cl1-r
PORT#/ALPA/C,

TID#, LU# Num(LDEV#...) P/S, Status, Fence, LDEV#, P-Seq# P-LDEV#

CL1-R/ ce/15,

15,

7

5(100,101..)

P-VOL PAIR

NEVER

100,

5678

200

CL1-R/ ce/15,

15,

6

5(200,201..)

SMPL ----

----

----

----

-----


# raidscan -p cl1-r -f
PORT#/ALPA/C, TID#,

LU#

Num(LDEV#...) P/S, Status,

Fence, LDEV#, Vol.Type

CL1-R/ ce/15,

15,

7

5(100,101..)

P-VOL PAIR

NEVER

100,

OPEN-3

CL1-R/ ce/15,

15,

6

5(200,201..)

SMPL ----

----

----

OPEN-3

Figure 4.28 Raidscan Command Examples for Fibre-Channel Ports

# ls /dev/rdsk/* | raidscan -find
DEVICE_FILE UID S/F PORT TARG LUN SERIAL LDEV PRODUCT_ID
/dev/rdsk/c0t0d4 0 S CL1-M 0 4 31168 216 OPEN-3-CVS-CM
/dev/rdsk/c0t0d1 0 S CL1-M 0 1 31168 117 OPEN-3-CVS
/dev/rdsk/c1t0d1 - - CL1-M - - 31170 121 OPEN-3-CVS

Figure 4.29 Example of -find Option for Raidscan

Output of the raidscan command:

„

SCSI: Port#, TargetID#, Lun# = port ID, TID, and LU number (LUN)

„

Fibre: Port#, ALPA/C, TID#, LU# = port ID, arbitrated loop phys. address, TID, LUN. For
further information on fibre-to-SCSI address conversion, see Appendix C.
Note: For ShadowImage, raidscan displays MU# for each LUN (e.g., LUN 7-0, 7-1, 7-2).

„

Num(LDEV#…) = number of LDEVs and LDEV ID for the LUSE volume

„

P/S = volume attribute

„

Status = status of the paired volume

„

Fence (TrueCopy only) = fence level

„

P-Seq# = serial # of the storage system which contains the partner volume of the pair

„

P-LDEV# = LDEV number of the partner volume of the pair