294

Chapter 4 Performing CCI Operations

Parameter

Value

Returned values

When the -nowait option is specified:

Normal termination: 0: The status is NOWAIT.

Abnormal termination: other than 0 to 127, refer to the execution logs for error details.
When the -nowait option is not specified:

Normal termination: 0: The status is DONE (completion of synchronization).

1: The status is TIMEOUT (timeout).

2: The status is BROKEN (Q-marker synchronized process is rejected).

3: The status is CHANGED (Q-marker is invalid due to resynchronize).

Abnormal termination: other than 0 to 127, refer to the execution logs for error details.

Restriction

Specified volume must be PVol with status PAIR. Other cases reply with error (EX_INVVOL). It is

possible to issue pairsysncwait from SVOL side with -m .

Table 4.49 Specific Error Code for Pairsyncwait

Category

Error Code

Error Message

Recommended Action

Value

Volume status
Unrecoverable

EX_INVVOL

Invalid volume status

Confirm pair status using pairdisplay -l. 222

Note: Unrecoverable errors are fixed and will not be resolved, even after re-executing the
command. If the command failed, the detailed status will be logged in the CCI command log
($HORCC_LOG) (see Table A.2), even if the user script has no error handling.