Chapter 4 Performing CCI Operations

Recovery from EX_EWSTOT: If horctakeover failed with [EX_EWSTOT], recover as follows:

1. Wait until the SVOL state becomes “SVOL_PSUS” by using the return code of “pairvolchk

-g -ss” command, and try to the start-up again for the HA Control Script.

2. Make an attempt to re-synchronize the original PVOL based on SVOL using “pairresync -g

-swaps -c “ for a fast failback operation.
If this pairresync operation fails with [EX_CMDRJE] or [EX_CMDIOE], there will be a cause
of ESCON link down and/or site failure.

If this operation fails, then HA Control Script reports the following message: ”After a
recovery from failure, please try ‘pairresync -g -swaps -c ‘ command.”
To avoid above recovery steps, a timeout value should be a greater than (or equal) to the
start-up timeout value for the HA control script.