Hitachi TAGMASTORE MK-90RD011-25 User Manual
Page 148

130
Chapter 3 Preparing for CCI Operations
5. Execute the HORCM installation command: # /HORCM/horcminstall.sh
6. Verify installation of the proper version using the raidqry command:
# raidqry -h
Model: RAID-Manager/HP-UX
Ver&Rev: 01-22-03/02
Usage: raidqry [options]
Version Up. To install a new version of the CCI software:
1. Confirm that HORCM is not running. If it is running, shut it down:
One CCI instance: # horcmshutdown.sh
Two CCI instances: # horcmshutdown.sh 0 1
If Hitachi TrueCopy/ShadowImage commands are running in the interactive mode,
terminate the interactive mode and exit these commands using -q option.
2. Insert the installation medium (e.g., CD-ROM) into the proper I/O device.
3. Move to the directory containing the HORCM directory (e.g., # cd / for root directory).
4. Copy all files from the installation medium using the cpio command:
# cpio -idmu < /dev/XXXX XXXX = I/O device
Preserve the directory structure (d flag) and file modification times (m flag) and copy
unconditionally (u flag). For floppy disks, load them sequentially, and repeat the
command. An input/output device name of floppy disk designates a surface partition of
the raw device file (unpartitioned raw device file).
5. Execute the HORCM installation command: # /HORCM/horcminstall.sh
6. Verify installation of the proper version using the raidqry command:
# raidqry -h
Model: RAID-Manager/HP-UX
Ver&Rev: 01-22-03/02
Usage: raidqry [options]