Hitachi TAGMASTORE MK-90RD011-25 User Manual
Page 311

Hitachi Command Control Interface (CCI) User and Reference Guide
293
Parameter
Value
Options
-h: Displays Help/Usage and version information.
-q: Terminates the interactive mode and exits the command.
-z or -zx (OpenVMS cannot use the -zx option): Makes the raidar command enter the interactive mode.
The -zx option guards performing of the HORCM in the interactive mode. When this option detects a
HORCM shut down, interactive mode terminates.
-I[H][M][instance#] or -I[TC][SI][instance#] Specifies the command as [HORC]/[HOMRCF], and is used
to specify the instance# of HORCM.
-g
for the specified group unless the -d
-d
option is specified, the command is executed for the specified paired logical volume.
-d[g]
specified raw_device. If the specified raw_device is found, the command is executed on the paired logical
volume (-d) or group (-dg). This option is effective without specification of “-g
specified the raw_device is contained in two or more groups, the command is executed on the first group.
-d[g]
the specified LDEV, and if the specified LDEV is contained in the group, the command is executed on the
paired logical volume (-d) or group (-dg). This option is effective without specification of “-g
option. If the specified LDEV is contained in two or more groups, the command is executed on the first
group. The
-m
marker as the result of execution of pairsyncwait because of timeout or “-nowait”, the application can
reconfirm the completion of Async transfer by using pairsysncwait with Q-marker. If the application does
not specify Q-marker, CCI uses the latest sequence # when CCI receives pairsysncwait. It is also possible
to wait for the completion from SVOL side with this option.
Q-Marker format: = iissssssss, where ii = incarnation # of pair volume, and ssssssss = PVOL serial #.
-t
ms. MCU gets the latest sequence # from RCU at regular interval.
-nowait: Gets the latest sequence # of MCU PVol and CTGID without waiting. When this option is
specified, the latest sequence # of MCU PVol is reported immediately, and -t
-nomsg: Suppresses messages to be displayed when this command is executed from a user program.
This option must be specified at the beginning of the command arguments.
-fq: Displays the number of remaining Q-Markers within the CT group by adding “QM-Cnt” to the last
column. “QM-Cnt” will be shown as follows:
• In case of specifying “-nowait -fq”
“QM-Cnt” will be shown as the number of remaining Q-Marker at this time within CT group.
• In case of specifying “-nowait -m
“QM-Cnt” will be shown as the number of remaining Q-Marker from the specified
group.
• In case of “TIMEOUT” without “-nowait”
“QM-Cnt” will be shown as the number of remaining Q-Marker at this timeout within CT group.
“QM-Cnt” will be shown as “-”, if the status for Q-Marker is invalid (i.e. status is “BROKEN” or
“CHANGED”).
Example:
# pairsyncwait -g oradb -nowait -fq
UnitID CTGID Q-Marker Status Q-Num QM-Cnt
0 3 01003408ef NOWAIT 2 120
# pairsyncwait -g oradb -nowait -m 01003408e0 -fq
UnitID CTGID Q-Marker Status Q-Num QM-Cnt
0 3 01003408e0 NOWAIT 2 105
# pairsyncwait -g oradb -t 50 -fq
UnitID CTGID Q-Marker Status Q-Num QM-Cnt
0 3 01003408ef TIMEOUT 2 5