Hitachi TAGMASTORE MK-90RD011-25 User Manual
Page 239

Hitachi Command Control Interface (CCI) User and Reference Guide
221
Category
Error Code
Error Message
Recommended Action
Value
EX_EVOLCE
Pair Volume combination error
Confirm pair status using pairdisplay, and
change combination of volumes.
235
EX_VOLCUR
S-VOL currency error
Check volume list to see if an operation
was directed to the wrong S-VOL.
225
EX_VOLCUE
Local Volume currency error
Confirm pair status of the local volume.
224
Unrecoverable
EX_VOLCRE
Local and Remote Volume currency
error
Confirm pair status of remote and local
volumes using pairdisplay command.
223
Timer
Recoverable
EX_EWSTOT
Timeout waiting for specified status
Increase timeout value using -t option.
233
Note: Unrecoverable errors are fixed and will not be resolved, even after re-executing the
command. If the command failed, the detailed status will be logged in the CCI command log
($HORCC_LOG) (see Table A.2), even if the user script has no error handling.