2 raidar command – Hitachi TAGMASTORE MK-90RD011-25 User Manual
Page 252
234
Chapter 4 Performing CCI Operations
4.11.2 Raidar Command
The raidar command displays configuration, status, and I/O activity information for the
specified port/TID(s)/device(s) at the specified time interval. The configuration information
is acquired directly from the storage system (not from the configuration definition file).
Table 4.25 lists and describes the raidar command parameters. Figure 4.30 shows an
example of the raidar command and its output.
Note: The I/O activity of a TrueCopy S-VOL in the COPY or PAIR state includes TrueCopy
remote I/Os (update copy operations) in addition to host-requested I/Os. The I/O activity of
a ShadowImage S-VOL in the COPY or PAIR state includes only host-requested I/Os
(ShadowImage update copy operations are excluded). The I/O activity of a P-VOL or simplex
volume includes only host-requested I/Os. If state changed into SMPL in S-VOL (COPY, PAIR)
I/O actively, and then I/O activity of the between is reported in the SMPL state.
Table 4.25 Raidar Command Parameters
Parameter Value
Command Name
raidar
Format
raidar { -h
⎪ -q ⎪ -z ⎪ -p Options -h: Displays Help/Usage and version information. option guards performing of the HORCM in the interactive mode. When this option detects a HORCM shutdown, interactive mode terminates. for specifying instance# of HORCM. CL1-O, CL2-I, CL2-O). For USP V/VM: CL3-a to CL3-r, or CLG-a to CLG-r for the expanded port. For TagmaStore USP V/VM: CL3-a to CL3-r, or CLG-a to CLG-r for the expanded port. For TagmaStore NSC: CL3-a to CL3-h, or CL8-a to CL8-h for the expanded port. For 9900V: CL3-a to CL3-r, or CL4-a to CL4-r for the expanded port. conversion information). [mun]: Specifies the MU number of the specified LUN (ShadowImage only). -pd[g] -pdg option is used to show a LUN on the host view by finding a host group (9900V and later).
-q: Terminates the interactive mode and exits the command.
-z or -zx (OpenVMS cannot use the -zx option): Makes raidar command enter interactive mode. The -zx
-I[H][M][instance#] or -I[TC][SI][instance#] Specifies the command as [HORC]/[HOMRCF], and used
-p
The port is not case sensitive (e.g. CL1-A= cl1-a= CL1-a= cl1-A, CL3-a= CL3-A= cl3-a= cl3-A).
-s [interval] or -sm [interval]: Designates the time interval in seconds.
-s: Interprets the time interval as seconds.
-sm: Interprets the time interval as minutes.
[ interval]: Designates the time interval value (1 to 60). If not specified, the default interval (3) is used.
[count]: Designates number of repeats. When omitted, this command repeats until CNTL-C.