Hitachi Command Control Interface (CCI) User and Reference Guide

253

# raidvchkscan -p CL1-A -v gflag

Å Example of -v gflag option.

PORT# /ALPA/C TID# LU# Seq# Num LDEV# GI-C-R-W-S PI-C-R-W-S R-Time
CL1-A / ef/ 0 0 0 2332 1 0 E E D D E E E D D E 365
CL1-A / ef/ 0 0 1 2332 1 1 E E D D E E E D D E -
CL1-A / ef/ 0 0 2 2332 1 2 E E D D E E E D D E 0

Figure 4.43 Raidvchkscan Command Example with -v gflag Option

Output of the raidqvchkscan command with -v gflag option:

„

GI-C-R-W-S: This displays the flags for guarding as for the target volume.

I Æ E: Enabled for Inquiry command.
D: Disabled for Inquiry command.
C Æ E: Enabled for Read Capacity command.
D: Disabled for Read Capacity command.
R Æ E: Enabled for Read command.
D: Disabled for Read command.
WÆ E: Enabled for Write command.
D: Disabled for Write command.
SÆ E: Enabled for becoming the SVOL.
D: Disabled for becoming the SVOL.

„

PI-C-R-W-S: This displays the permission flags that show whether each mode flag can be
changed to enable or not.

I Æ E: ”I” flag can be changed to enable.
D: ”I” flag cannot be changed to enable.
C Æ E: ”C” flag can be changed to enable.
D: ”C” flag cannot be changed to enable.
R Æ E: ”R” flag can be changed to enable.
D: ”R” flag cannot be changed to enable.
WÆ E: ”W” flag can be changed to enable.
D: ”W” flag cannot be changed to enable.
SÆ E: ”S” flag can be changed to enable.
D: ”S” flag cannot be changed to enable.

„

R-Time: This displays the retention time for write protect, in units of day. The hyphen
(-) shows that the retention time is infinite. APP will be able to know whether the target
volume is denied to change to writing enable by referring “R-Time”.

Audit lock status is shown as the retention time plus 1000000.
“R-Time + 1000000” shows the retention time with Audit lock status.