Chapter 4 Performing CCI Operations
Parameter Value
Options
-h: Displays Help/Usage and version information.
-q: Terminates the interactive mode and exits the command.
-z or -zx (OpenVMS cannot use the -zx option): Makes the raidscan command enter interactive mode.
The -zx option guards performing of the HORCM in interactive mode. When this option detects a HORCM
shut down, interactive mode terminates.
-I[H][M][instance#] or -I[TC][SI][instance#] Specifies the command as [HORC]/[HOMRCF], and used for
specifying instance# of HORCM.
-p
CL2-A to CL2-R (excluding CL1-I, CL1-O, CL2-I, CL2-O)
For USP V/VM: CL3-a to CL3-r, or CLG-a to CLG-r for the expanded port.
For TagmaStore USP V/VM: CL3-a to CL3-r, or CLG-a to CLG-r for the expanded port.
For TagmaStore NSC: CL3-a to CL3-h, or CL8-a to CL8-h for the expanded port.
For 9900V: CL3-a to CL3-r, or CL4-a to CL4-r for the expanded port.
The port is not case sensitive (e.g. CL1-A= cl1-a= CL1-a= cl1-A, CL3-a= CL3-A= cl3-a= cl3-A).
This option must be specified if “-find” or “-pd
[hgrp] is specified to display only the LDEVs mapped to a host group on a port (9900V and later).
-pd[g]
storage system to which the specified device can be connected, and scans the port of the storage system
which corresponds with the unit ID that searches the unit ID from Seq#. This option must be specified if the
“-find” option will not be specified. If this option is specified, the following -s
-pdg option is used to show a LUN on the host view by finding a host group (9900V and later).
-s
unit ID which is contained for “-p
of the storage system which corresponds with the unit ID that searches the unit ID from Seq#. If this option
is specified, then the unit ID which is contained in “-p
-t
applies to all target IDs.
-l
applies to all LUNs. If this option is specified, the TID must also be specified.
-f or -ff: Specifies display of volume-type for a display column. If this is specified, -f[g] [d] option is invalid.
-fx: Displays the LDEV number in hexadecimal notation.
-fg: Specifies display of group_name for a display column. This option searches a group on the
configuration definition file (local CCI instance) from the scanned LDEV, and displays a group_name when
the scanned LDEV is contained in the group. If this option is specified, the -f[f] option is not allowed and
the -f[d] option is invalid.
-fd: Displays the Device_File that was registered to the group of the HORCM in the output, based on the
LDEV (as defined in local instance config. def. file). If this option is specified, -f[f][g] option is not allowed.
-fe: Displays the serial# (E-Seq#) and LDEV# (E-LDEV#) of the external LUNs only mapped to the LDEV.
If the external LUN mapped to the LDEV on a specified port does not exist, then this option will do nothing.
Also if this option is specified, -f[f][g][d] option is not allowed. Display example:
# raidscan -p cl1-a-0 -fe -CLI
PORT# /ALPA/C TID# LU# Seq# Num LDEV# P/S Status Fence E-Seq# E-LDEV#
CL1-A-0 ef 0 0 48 62468 2 256 SMPL - - 30053 17
CL1-A-0 ef 0 0 49 62468 2 272 SMPL - - 30053 23
CL1-A-0 ef 0 0 50 62468 1 288 SMPL - - 30053 28
-CLI: Specifies display for command line interface (CLI). This option displays to the same position that
defined number of columns, and displays one header. The delimiters between columns are displayed as
spaces or hyphens (-). Display example:
Port# TargetID# Lun# Seq# Num LDEV# P/S Status Fence P-Seq# P-LDEV#
CL1-C 1 0 30053 1 274 SMPL - - - -
CL1-C 2 2 30053 1 260 P-VOL PAIR NEVER 30053 268
CL1-C 2 3 30053 1 261 P-VOL PAIR NEVER 30053 269
-m
mirror descriptor for UR, -m
environment. If you want to display all cascading mirror descriptor, specify “-m all” for displaying all MUs.
-pi
find option will be ignored a raw device file provided via STDIN, and
-find [op] [MU#]: Executes the specified [op] using a raw device file provided via STDIN. If -pi
option is specified, this option does not use a strings via STDIN, and -pi