beautypg.com

4 port troubleshooting, Roubleshooting – PLANET WGSW-52040 User Manual

Page 90

background image

Switch2:

Switch2(config)#interface ethernet 1/9

Switch2(Config-If-Ethernet1/9)#speed-duplex force100-full

Switch2(Config-If-Ethernet1/9)#exit

Switch2(config)#interface ethernet 1/10

Switch2(Config-If-Ethernet1/10)#speed-duplex force1g-full

Switch2(Config-If-Ethernet1/10)#exit

Switch2(config)#monitor session 1 source interface ethernet 1/8;1/9

Switch2(config)#monitor session 1 destination interface ethernet 1/10

Switch3:

Switch3(config)#interface ethernet 1/12

Switch3(Config-If-Ethernet1/12)#speed-duplex force100-full

Switch3(Config-If-Ethernet1/12)#exit

7.4 Port Troubleshooting

Here are some situations that frequently occurs in port configuration and the advised solutions:

Two connected fiber interfaces won’t link up if one interface is set to auto-negotiation but

the other to forced speed/duplex. This is determined by IEEE 802.3.

The following combinations are not recommended: enabling traffic control as well as

setting multicast limiting for the same port; setting broadcast, multicast and unknown

destination unicast control as well as port bandwidth limiting for the same port. If such

combinations are set, the port throughput may fall below the expected performance.









7-12