Step 3: Login to the switch.
Login to the Web configuration interface. Valid login name and password are required, otherwise the switch
will reject HTTP access. This is a method to protect the switch from unauthorized access. As a result, when
Telnet is enabled for configuring and managing the switch, username and password for authorized Telnet
users must be configured with the following command:

username privilege [password (0|7) ]


To open the local authentication style with the following command: authentication line web login local.

Privilege

option must exist and just is 15. Assume an authorized user in the switch has a username of

“admin”, and password of “admin”, the configuration procedure should like the following:

Switch>enable

Switch#config

Switch(config)#username admin privilege 15 password 0 admin
Switch(config)#authentication line web login local


The Web login interface of WGSW-52040 is as below:

Figure 3-10 Web Login Interface




3-17