PLANET WGSW-52040 User Manual
Page 123
![background image](https://www.manualsdir.com/files/865181/content/doc123.png)
ethernet-oam period
no ethernet-oam period
Configure transmission period of
OAMPDU (optional), no command
restores the default value.
ethernet-oam timeout
no ethernet-oam timeout
Configure timeout of EFM OAM
connection, no command restores
the default value.
2. Configure link monitor
Command Explanation
Port mode
ethernet-oam link-monitor
no ethernet-oam link-monitor
Enable link monitor of EFM OAM, no
command disables link monitor.
ethernet-oam errored-symbol-period
{threshold low
no ethernet-oam errored-symbol-period
{threshold low | window }
Configure the low threshold and
window period of errored symbol
period event, no command resotores
the default value. (optional)
ethernet-oam errored-frame-period {threshold
low
no ethernet-oam errored-frame-period
{threshold low | window }
Configure the low threshold and
window period of errored frame
period event, no command resotores
the default value.
ethernet-oam errored-frame {threshold low
no ethernet-oam errored-frame {threshold low
| window }
Configure the low threshold and
window period of errored frame
event, no command resotores the
default value. (optional)
ethernet-oam errored-frame-seconds
{threshold low
no ethernet-oam errored-frame-seconds
{threshold low | window }
Configure the low threshold and
window period of errored frame
seconds event, no command
resotores the default value.
(optional)
14-45