Troubleshooting

12-3

12

Printouts are too dark.

Have you changed the
density?

Select appropriate density level.

3-9
9-68

Run [Calibration].

9-74

Run [Drum Refresh1].

9-72

Run [Developer Refresh].

9-73

Copies have a moire
pattern (dots grouped
together in patterns
and not aligned
uniformly).

Is the original a printed
photograph?

Set the image quality to [Printer
Output] or [Book/Magazine] in
[Photo].

3-9

Printouts are not
clear.

Did you choose appropriate
image quality for the original?

Select appropriate image quality.

3-9

Dirt on the print side
of the paper.

Is the platen or the document
processor dirty?

Clean the platen or the document
processor.

11-15

Is the conveying guide dirty?

Clean the conveying guide.

11-18

Run [Drum Refresh1].

9-72

Run [Developer Refresh].

9-73

Printouts are fuzzy.

Is the machine being used in
very humid conditions?

Use in an environment that has
suitable humidity.

Run [Drum Refresh1].

9-72

Images are skewed.

Are the originals placed
correctly?

When placing originals on the
platen, align them with the original
size indicator plates.

2-45

When placing originals in the
optional document processor, align
the original width guides securely
before placing the originals.

2-45

Is the paper loaded
correctly?

Check the position of the paper
width guides.

2-28

Symptom

Checkpoints

Corrective Actions

Reference

Page