Drum refresh1, E 9-72), Drum refresh1 …9-72 – TA Triumph-Adler DC 2435 User Manual
Page 370
Default Setting (System Menu)
9-72
Use the procedure below for normal adjustment.
1
Press the System Menu key.
2
Press [
], [Adjustment/Maintenance], [
] and then [Next] of Tone Curve Adjustment.
3
Press [Start]. A pattern is printed.
Check that the number "1" is printed at the bottom of the pattern.
4
As shown in the illustration, place the printed side down on the
platen with the edge with the arrows toward the back.
5
Press [Start]. The pattern is read and adjustment begins.
The second pattern is output.
6
Check that the number "2" is printed at the bottom of the pattern
and repeat steps 4 to 6 to read the pattern.
7
Press [OK] in the adjustment end confirmation screen.
Drum Refresh1
Refresh the drum when image blur appear on images in copies. Takes about 90 seconds.
NOTE:
Drum Refresh1 cannot be performed while printing. Execute Drum Refresh1 after the printing is done.
To use [Drum Refresh1], load Ledger or A3 size paper into the Multi Purpose tray.
Use the procedure below to refresh the drum.
1
Press the System Menu key.
2
Press [
], [Adjustment/Maintenance].
3
Press [
], [Next] of Drum Refresh1.
4
Press [Execute] to perform Drum Refresh.
5
After Drum Refresh is completed, press [OK] to return to the Adjustment/Maintenance screen.